iControl2 error codes

Translation of the iControl2 error codes, that are displayed on the iControl2 Panel, into the Fischer Panda J1939 event codes.

iControl2 j1939 error codes up to Release PiC2_2.34
iControl2 PaneliControl2 j1939Meaning
526Starting failed/Engine revolution (RPM) low
9151Watchdog error
1273Winding temperature high
13152Winding temperature out of range
1474Exhaust temperature high
15153Exhaust temperature out of range
1672Engine temperature high
177Engine oil pressure low
1825Starter battery voltage low
1928unexpected stop/problem with fuel supply
2269Emergency stop
23154Engine temperature out of range
30155Inverter temperature high (L1, L2, L3 or DC)
31156Inverter overload (HP1 generators)
34142Engine fault, error message from engine control unit
36160AC current L1 high
37161AC current L2 high
38162AC current L3 high
39163Inverter DC link overloaded
4065AC voltage high L1, (L2, L3)
411AC voltage low L1, (L2, L3)
42164Inverter DC link overvoltage
66165Redundant emergency stop
100166Communication lost
207150Init failed (no generator type is selected)

iControl2 j1939 error codes from Release PiC2_2.35
iControl2 PanelfpControlMeaning
526Starting failed/Engine revolution (RPM) low
9151Watchdog error
1273Winding temperature high
139Winding temperature out of range
1474Exhaust temperature high
1510Exhaust temperature out of range
1672Engine temperature high
177Engine oil pressure low
1825Starter battery voltage low
1926unexpected stop/problem with fuel supply
225Emergency stop
238Engine temperature out of range
30152Inverter temperature high (L1, L2, L3 or DC)
3167Inverter overload (HP1 generators)
34142Engine fault, error message from engine control unit
3667AC current L1 high
3796AC current L2 high
38100AC current L3 high
39163Inverter DC link overloaded
4065, (94, 98)AC voltage high L1, (L2, L3)
411, (30, 34)AC voltage low L1, (L2, L3)
42164Inverter DC link overvoltage
66165Redundant emergency stop
100166Communication lost
207150Init failed (no generator type is selected)