Event Description
The AC current on phase L1 is above its upper limit.
Error view
Languages: German | English | Chinese | Spanish | French | Symbolic






Elements of the Event page

| Event symbol | Consequences of the event |
| When an error event occurs, the monitored value has reached its error limit. Error events shutdown the generator | |
| When a warning event occurs, the monitored value has reached its warning limit. Warning Events don’t shutdown the generator | |
| An Information event is for information purpose only and has no effect on the generator operation |
| Device that triggers this event: | Generator control or inverter |
| Warning | No |
| Error | Yes |
Safety instructions
These symbols are used to warn of the possibility of personal injury of lethal danger during certain maintenance work or operations. See Users Manual for Safety Information and complete operating information. Read these instructions carefully. For further information click on the corresponding symbol. Each link opens a new tab.


Causes and solutions
General for all control systems
| Common causes | Possible solutions |
| Too large electrical load at the output | Reduce the load to ist nominal generator value. Follow the nominal power rating on the rating plate |
Specific for the iSeries – Inverter overload (HP1 generators)
- Overload on the output L1
| Common causes | Possible solutions |
| Short circuit outside of the inverter | Disconnect the output of the inverter and check if the issue persists. If the issue no longer exists, then there is a short outside of the generator system. |
| Generator issue: – Short circuit inside the inverter – or an issue with the winding can be the cause of a defective inverter – A issue with the cable from the winding to the inverter | Contact Fischer Panda or one of the service partners for the next steps |
Distributors and Services
For any service or maintenance questions, please contact Fischer Panda or our worldwide partners.