Event Description
The current at the output for the DC supply voltage of the inverter is below its lower limit.
Warning view
Languages: German | English | Chinese | Spanish | French | Symbolic
Warning illustrated by the example of the english and the symbolic view:


Error view
Languages: German | English | Chinese | Spanish | French | Symbolic






Elements of the Event page

| Event symbol | Consequences of the event |
| When an error event occurs, the monitored value has reached its error limit. Error events shutdown the generator | |
| When a warning event occurs, the monitored value has reached its warning limit. Warning Events don’t shutdown the generator | |
| An Information event is for information purpose only and has no effect on the generator operation |
| Device that triggers this event: | Generator control |
| Warning | Yes |
| Error | No |
Safety instructions
These symbols are used to warn of the possibility of personal injury of lethal danger during certain maintenance work or operations. See Users Manual for Safety Information and complete operating information. Read these instructions carefully. For further information click on the corresponding symbol. Each link opens a new tab.


Causes and solutions
| Common causes | Possible solutions |
| Loose connector at the control cable to the inverter | Check the connector of the control cable |
| Loose connection at GND or +12 V of the control cable to the inverter | Check the individual wires of the control cable to inverter for loose connections |
Distributors and Services
For any service or maintenance questions, please contact Fischer Panda or our worldwide partners.