Event Description
An error in the control loop for the converter power electronics was detected.
Error view

Elements of the Event page

| Event symbol | Consequences of the event |
| When an error event occurs, the monitored value has reached its error limit. Error events shutdown the generator | |
| When a warning event occurs, the monitored value has reached its warning limit. Warning Events don’t shutdown the generator | |
| An Information event is for information purpose only and has no effect on the generator operation |
| Device that triggers this event: | Converter Control Unit (part of the Power Electronic Unit) |
| Warning | No |
| Error | Yes |
Safety instructions
These symbols are used to warn of the possibility of personal injury of lethal danger during certain maintenance work or operations. See Users Manual for Safety Information and complete operating information. Read these instructions carefully. For further information click on the corresponding symbol. Each link opens a new tab.

Causes and solutions
| Common causes | Possible solutions |
| Wrong parameter. | Contact the Fischer Panda Service. |
| Wrong Hardware compilation. | Contact the Fischer Panda Service. |
| Counterclockwise rotating field on the Hybrid Charger. | Check whether there is a counterclockwise rotating field on the Hybrid Charger. Check whether the current software release is installed on the Hybrid Charger. Contact to the Fischer Panda specialist dealer is necessary. The Fischer Panda specialist dealer must be informed about the software version of the hybrid charger. This can be found on the Device Browser Page of the fpControl panel in menu generator > show system-devices. The Device ID for the Hybrid Charger is 14. |