Module for the connection of the fpCAN to an external NMEA 2000® network.
Fischer Panda part number: 0031409
Product description
The »Communication Interface CI – NMEA 2000®« manages the communication between the »fpCAN« and an external NMEA 2000® network. The interface protects the internal »fpCAN« by filtering the data from the external NMEA 2000® network. The »fpCAN« and the NMEA 2000® network are galvanically isolated. The »fpControl CI NMEA 2000®« is powered by the »fpCAN«.

Application
Fischer Panda Generators equipped with xControl, iControl2 or fpControl.
Specification
Housing
ABS Plastic
Terminal assignment
| 2 x RJ45 | Supply voltage and internal fpCAN (FP CAN BUS 1) |
| 1 x 5-pin Phoenix Contact socket | NMEA 2000® network (USER CAN BUS) |
| 2 x RJ45 | Alternative sockets for NMEA 2000® network (FP CAN BUS 2) |


fpCAN Bus connection
Pin assignment of »FP CAN BUS 1«
Internal fpCAN, RJ45 socket.
| Pin | Line |
| 1 | CAN-High |
| 2 | CAN-Low |
| 3 | GND |
| 4 | Wake up |
| 5 | Bus power |
| 6 | GND |
| 7 | GND |
| 8 | Bus power |
NMEA 2000® network connection
Pin assignment of »USER CAN BUS«
NMEA 2000® network, 5-pin Phoenix Contact socket.
The electrical interface for the NMEA 2000® network (USER CAN BUS) is labelled directly on the printed circuit board:
| Pin | Line | Label |
| 1 | Power source common | NET_C |
| 2 | CAN High signal line | NET-H |
| 3 | CAN Low signal line | NET-L |
| 4 | Shield | SHIELD |
| 5 | Power source positive | NET-S |
Pin assignment of the 5-pin male NMEA 2000® connector (M12) that is part of the Adapter cable fpCAN/NMEA 2000®:
| Pin | Line | Color |
| 1 | Shield | — |
| 2 | NET-S | Power source positive | Red |
| 3 | NET-C | Power source common | Black |
| 4 | NET-H | CAN High signal line | White |
| 5 | NET-L | CAN Low signal line | Blue |

Pin assignment of »FP CAN BUS 2«
Alternative connection for the external NMEA 2000® network, RJ45 socket. The »FP CAN BUS 2« is parallel connected to the »USER CAN BUS«. It can be used to connect the NMEA 2000® network via RJ45 plug.
The external CAN Bus must be terminated. This can be achieved by a terminating resistor in the second RJ45 socket.
| Pin | Line |
| 1 | CAN-High |
| 2 | CAN-Low |
| 3 | GND |
| 4 | Wake up |
| 5 | Bus power |
| 6 | GND |
| 7 | GND |
| 8 | Bus power |
Rotary coding switch
The rotary coding switch is used to add an offset to the start address for the address claiming process.
Default setting: Rotary coding switch in position »0«. No offset is added to the start address.
Alternative Setting: Rotary coding switch in a position not equal to »0«: [start address] = [position of the rotary coding switch] * 16.
DIP switch
The DIP switch is reserved for future projects.
Environmental specifications and physical data
| Storage temperature | -30 °C to +60 °C |
| Operating temperature | -20 °C to +50 °C |
| Operation type | nonstop |
| Mounting position | any |
| Supply voltage | 12 V or 24 V, Automotive (12–13,5 V or 24–28 V) |
| Nominal current consumption | < 32 mA @ 12 V < 17 mA @ 24 V |
| Housing | ABS Plastic |
| Protection class | IP30 |
| Overall dimensions | 151 x 80 x 60 mm (L x B x H) |
| Weight | 0,25 kg |
| Circuit board | FP1409 |
Accessories
fpCAN patch cable
Available in different lengths:
| Length | Fischer Panda part number |
| 25 m | 0013474 |
| 15 m | 0004686 |
| 10 m | 0013473 |
| 6 m | 0013472 |
| 3 m | 0013471 |
| 1 m | 0013470 |
| 0,5 m | 0013468 |
| 0,2 m | 0013466 |
Adapter cable fpCAN/NMEA 2000® 0,3 m
Fischer Panda article number 0024737.

Terminating resistor
fpCAN terminating resistor 120 Ohm with RJ45 connector, red RAL 3000 with FP logo. Fischer Panda article number 0003022.

Adapter cable iControl2
Fischer Panda article number 0008899.