Skip to content

Fischer Panda

Knowledge Base

  • Event Codes
    • Event Codes
    • iControl2 error codes
    • Inverter blink codes
  • fpControl View
  • fpControl
    • Application Notes fpC
    • Technical Datasheets fpC
    • Generator type codes
  • iControl2
    • Application Notes iC2
    • Technical Datasheets iC2
  • Inverter
    • Application Notes Inverter
    • Technical Datasheets Inverter
  • Communication
    • SAE J1939
    • NMEA 2000®
    • Victron GX
    • Multifunction Displays
  • System
  • Glossary
  • Service

Category Archives: Application Notes fpC

Start repetitions in automatic start mode

The fpControl system offers the possibility to carry out several start-up attempts in the automatic start mode.

Posted byFischer PandaNovember 26, 2020November 26, 2020Posted inApplication Notes fpC, fpControl

The fpControl cooldown phase

The »fpControl GC-S« has an integrated cooldown phase to cool the engine down before it is switched off. All generators with fpControl have this feature. The duration of the cooldown phase can be set in the service menu of the »fpControl CP-G«. So the cool down phase can be adapted to individual applications.

Posted byFischer PandaOctober 2, 2020October 30, 2020Posted inApplication Notes fpC, fpControl

AGT UI control with BMS

You can connect a Fischer Panda AGT generator to a battery management system (BMS). In BMS UI mode the AGT can control either on voltage or on current.

Posted byFischer PandaSeptember 24, 2020October 30, 2020Posted inAGT, Application Notes fpC, fpControl

The tank refill function of fpControl

With the tank refill function of fpControl you can refill the integrated tank of the generator with diesel fuel from a separate additional tank.

Posted byFischer PandaSeptember 14, 2020November 10, 2020Posted inApplication Notes fpC, fpControl

The fpControl cold start aid

You can preheat the diesel engine with a cold start aid. This is necessary if the generator is started at an ambient temperature of less than -20 °C.

Posted byFischer PandaSeptember 8, 2020November 3, 2020Posted inApplication Notes fpC, fpControl

Shore power switch-over using the fpControl system

You can use the shore power switch-over to automatically switch the supply of your on-board network between the shore network and the generator. This switch-over is used if the mains voltage fails. When the mains voltage is restored, the switch-over can switch back to shore power.

Posted byFischer PandaSeptember 4, 2020November 3, 2020Posted inApplication Notes fpC, fpControl

fpControl software update

You can update the software of the generator control »fpControl Generator Control – Servo« (fpControl GC-S) and the software of the bus modules on the fpCAN. For this purpose, the software update files are transferred to the »fpControl GC-S«, which distributes the updates to the other bus modules.

Posted byFischer PandaApril 28, 2020December 4, 2020Posted inApplication Notes fpC, fpControl, Software Update

Adjusting the parameters for the battery loader with fpControl

You can set the charging curve parameters of the battery loader. This is necessary to adapt the battery loader to different battery types.

Posted byFischer PandaDecember 3, 2019November 9, 2020Posted inAGT, Application Notes fpC, fpControl

Configuring multifunctional outputs at fpControl

The generator control fpControl offers two multifunctional outputs. You can configure the function of these digital outputs in the service menu of the control panel. This is useful, for example, to extend the functionality of the generator control. For each of the two outputs several profiles are available.

Posted byFischer PandaNovember 29, 2019November 13, 2020Posted inApplication Notes fpC, fpControl

Setting the generator type code at fpControl

You can set the generator type code in service menu of the control panel. This is necessary to adapt the generator control fpControl to different generator types.

Posted byFischer PandaNovember 27, 2019October 30, 2020Posted inApplication Notes fpC, fpControl

Posts navigation

1 2 Older posts

News

  • Event 173 – BMS lost January 18, 2021
  • Event 172 – Synchronization Module offline December 18, 2020
  • Event 171 – Load Contactor switched off forced December 18, 2020
  • Start repetitions in automatic start mode November 26, 2020
  • Inverter blink codes November 13, 2020

Categories

  • AGT
  • Application Notes fpC
  • Application Notes Inverter
  • Communication
  • Event Codes
  • fpControl
  • iControl2
  • Inverter
  • Multifunction Displays
  • NMEA 2000®
  • SAE J1939
  • Software Update
  • System
  • Technical Datasheets fpC
  • Technical Datasheets iC2
  • Technical Datasheets Inverter
  • Victron GX

Archive

  • January 2021
  • December 2020
  • November 2020
  • October 2020
  • September 2020
  • August 2020
  • July 2020
  • June 2020
  • May 2020
  • April 2020
  • January 2020
  • December 2019
  • November 2019
  • October 2019
  • September 2019
  • July 2019
  • June 2019
  • May 2019
  • April 2019

Search …

Fischer Panda, Proudly powered by WordPress. Data Protection Policy
  • Site Terms & Conditions (Impressum)
  • Home
  • Glossary
  • Service