Event Description
At this digital output the voltage drop is monitored. The voltage drop between the output for the load relay and ground is below its lower limit.
Warning view
Languages: German | English | Chinese | Spanish | French | Symbolic
Elements of the Event page

| Event symbol | Consequences of the event |
| When an error event occurs, the monitored value has reached its error limit. Error events shutdown the generator | |
| When a warning event occurs, the monitored value has reached its warning limit. Warning Events don’t shutdown the generator | |
| An Information event is for information purpose only and has no effect on the generator operation |
| Device that triggers this event: | Generator control |
| Warning | Yes |
| Error | no |
Safety instructions
These symbols are used to warn of the possibility of personal injury of lethal danger during certain maintenance work or operations. See Users Manual for Safety Information and complete operating information. Read these instructions carefully. For further information click on the corresponding symbol. Each link opens a new tab.


Causes and solutions
| Common causes | Possible solutions |
| Short circuit at the load relay | Check the wiring and the function of the load relay and replace defective parts, if necessary |
Distributors and Services
For any service or maintenance questions, please contact Fischer Panda or our worldwide partners.