Application
The »fpControl Measurement Unit – MU-3ph / DC« is used for AC and DC generators.
Product description
On AC generators, the module measures the AC voltage up to 400 V in three phases and the AC current three times via an external sensor.
When used on DC generators, the module measures the DC voltage in two phases in the range from 12 V to 600 V and twice the DC current via an external sensor.
Connectors

| X202 | USB |
| X212 | Boost relay |
| X203 | Temperature sensor »TEMP 2« |
| X204 | Temperature sensor »TEMP 3« |
| X207 | external current transformer L3 »I L3« |
| X102 | DC voltage measurement (0…69 V DC) 3 x (+), 1 x (-) |
| X101 | AC: voltage measurement L1, L2, L3 and N (0…400 V ~ RMS) and PE or DC: 3 x (+), 1 x (-), 1 x PE (669 V DC) |
| X206 | external current transformer L2 »I L2« |
| X205 | external current transformer L1 »I L1« |
| X201 | Temperature sensor »TEMP 1« |
| X213 | AUX |
| X209 | Alternative for the external fpCAN (USER CAN BUS) |
| X210 | Supply voltage and »fpCAN« |
| X211 | Supply voltage and »fpCAN« |
Pin assignments
Pin assignment of »X212« for the boost relay
2-pin Phoenix Contact socket / plug with push-in spring cage connection terminals.
| Pin | Label | Line |
| 1 | BOOST + | Output boost relay |
| 2 | BOOST – | GND boost relay |
Pin assignment of »X207« for the external current transformer L3 »I L3«
3-pin Phoenix Contact socket / plug with push-in spring cage connection terminals.
| Pin | Label | Line |
| 1 | + | +5 V supply |
| 2 | IL3 | Sensor output |
| 3 | – | GND |
Pin assignment of »X102« for DC voltage measurement
- DC voltage measurement (0…69 V DC) 3 x (+), 1 x (-).
- 4-pin Phoenix Contact socket / plug with push-in spring cage connection terminals.
| Pin | Line |
| 1 | + |
| 2 | + |
| 3 | + |
| 4 | – |
Pin assignment of »X101« for AC / DC voltage measurement
5-pin Phoenix Contact socket / plug with push-in spring cage connection terminals.
| Pin | Label | Line |
| 1 | L1 (+) | L1 |
| 2 | L2 (+) | L2 |
| 3 | L3 (+) | L3 |
| 4 | N (-) | N |
| 5 | PE | PE |
Pin assignment of »X206« for the external current transformer L2 »I L2«
3-pin Phoenix Contact socket / plug with push-in spring cage connection terminals.
| Pin | Label | Line |
| 1 | + | +5 V supply |
| 2 | IL2 | Sensor output |
| 3 | – | GND |
Pin assignment of »X205« for the external current transformer L1 »I L1«
3-pin Phoenix Contact socket / plug with push-in spring cage connection terminals.
| Pin | Label | Line |
| 1 | + | +5 V supply |
| 2 | IL1 | Sensor output |
| 3 | – | GND |
Pin assignment of »X213« for »AUX«
2-pin Phoenix Contact socket / plug with push-in spring cage connection terminals.
| Pin | Line |
| 1 | AUX (+) |
| 2 | AUX (-) |
Pin assignment of »X209«, alternative for the external »fpCAN«
4-pin Phoenix Contact socket / plug with push-in spring cage connection terminals.
| Pin | Label | Line |
| 1 | – | GND |
| 2 | H | CAN high |
| 3 | L | CAN low |
| 4 | + | Bus power |
Pin assignment of »X210« and »X211« for supply voltage and »fpCAN«
RJ45 socket, Label »FP-CAN«.
Note: Bus termination is required if the »fpControl MU-3ph/DC« is the last module in the »fpCAN«.
| Pin | Line |
| 1 | CAN high |
| 2 | CAN low |
| 3 | GND |
| 4 | Wake up |
| 5 | Bus power |
| 6 | GND |
| 7 | GND |
| 8 | Bus power |
Environmental specifications and physical data
| Storage temperature | -30 °C – +60 °C |
| Operating temperature | -20 °C – +50 °C |
| Supply voltage | 12 V oder 24 V, Automotive (12–13,5 V oder 24–28 V) |
| Rated current consumption | < 139 mA @ 12 V < 91 mA @ 24 V |
| Housing | — |
| Protection class | IP30 |
| Overall dimensions | 114 mm x 72,5 mm (L x B) (Printed circuit board) |
| Weight | 0,094 kg (Printed circuit board) |
| FP part number | 0029859 |
| Printed circuit board | FP1901 |
Accessories
»fpCAN« patch cable
Available in different length. With a data transfer rate of 250 kbps and up to 30 nodes, the maximum cable length is 40 meters.
| Length | Fischer Panda part number |
| 25 m | 0013474 |
| 15 m | 0004686 |
| 10 m | 0013473 |
| 6 m | 0013472 |
| 3 m | 0013471 |
| 1 m | 0013470 |
| 0,5 m | 0013468 |
| 0,2 m | 0013466 |
Terminating resistor
The ends of the »fpCAN« network must be terminated with a 120 ohm resistor.
»fpCAN« terminating resistor 120 Ohm with RJ45 connector, red RAL 3000 with FP logo. Fischer Panda part number 0003022.