{"id":5557,"date":"2021-10-21T08:49:46","date_gmt":"2021-10-21T06:49:46","guid":{"rendered":"https:\/\/knowledgebase.fischerpanda.de\/?p=5557"},"modified":"2023-01-27T11:49:17","modified_gmt":"2023-01-27T10:49:17","slug":"event-178-converter-igbt-mosfet-driver-error","status":"publish","type":"post","link":"https:\/\/knowledgebase.fischerpanda.de\/?p=5557","title":{"rendered":"Event 178 \u2013 Converter IGBT\/MOSFET Driver Error"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Event Description<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">An error on the power switch (IGBT\/MOSFET) or in the power switch driver electronic was detected.<br><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>This event is usually tiggered by a driver interrupt in the hardware.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Error view<\/h4>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2023\/01\/event-178-symbolic.jpg\" alt=\"\" class=\"wp-image-6287\"\/><figcaption class=\"wp-element-caption\"><em>Symbolic view<\/em><\/figcaption><\/figure>\n\n\n\n<h4 class=\"clear wp-block-heading\">Elements of the Event page<\/h4>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"857\" height=\"154\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/05\/elements-of-an-error-page.png\" alt=\"Elements of an Event page: Event type, QR-Code, event number and event symbol or text.\" class=\"wp-image-776\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/05\/elements-of-an-error-page.png 857w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/05\/elements-of-an-error-page-300x54.png 300w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/05\/elements-of-an-error-page-768x138.png 768w\" sizes=\"(max-width: 857px) 100vw, 857px\" \/><figcaption class=\"wp-element-caption\"><em>Elements of an Event page: Event type, QR-Code, event number and event symbol or text<\/em><\/figcaption><\/figure>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Event symbol<\/strong><\/td><td><strong>Consequences of the event<\/strong><\/td><\/tr><tr><td><img decoding=\"async\" width=\"18\" height=\"17\" class=\"wp-image-66\" style=\"width: 18px;\" alt=\"Error symbol\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/shutdown-symbol.jpg\"> <strong>Error event<\/strong><\/td><td>When an <strong>error event<\/strong> occurs, the monitored value has reached its error limit. Error events <strong>shutdown the generator<\/strong><\/td><\/tr><tr><td><img decoding=\"async\" width=\"19\" height=\"18\" class=\"wp-image-67\" style=\"width: 19px;\" alt=\"Warning symbol\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/warning-symbol.jpg\"> <strong>Warning event<\/strong><\/td><td>When a <strong>warning event<\/strong> occurs, the monitored value has reached its warning limit. Warning Events <strong>don&#8217;t shutdown the generator<\/strong><\/td><\/tr><tr><td><img decoding=\"async\" width=\"17\" height=\"17\" class=\"wp-image-69\" style=\"width: 17px;\" alt=\"Information symbol\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/info-symbol.jpg\"> <strong>Information event<\/strong><\/td><td>An <strong>Information event<\/strong> is for information purpose only and has <strong>no effect on the generator operation<\/strong><\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Device that triggers this event:<\/strong><\/td><td><strong>Converter Control Unit <\/strong>(part of the Power Electronic Unit)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Warning<\/td><td>No<\/td><\/tr><tr><td><strong>Error<\/strong><\/td><td><strong>Yes<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h4 class=\"wp-block-heading\">Safety instructions<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">These symbols are used to warn of the possibility of personal injury of lethal danger during certain maintenance work or operations. See Users Manual for Safety Information and complete operating information. Read these instructions carefully. For further information click on the corresponding symbol. Each link opens a new tab. <\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft is-resized\"><a href=\"https:\/\/knowledgebase.fischerpanda.de\/?attachment_id=1652\" target=\"_blank\" rel=\"noreferrer noopener\"><img decoding=\"async\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/08\/read-manual_wei\u00df_klein.jpg\" alt=\"Observe the instructions in the manual\" class=\"wp-image-1652\" width=\"78\" height=\"78\"\/><\/a><figcaption class=\"wp-element-caption\">MANDATORY INSTRUCTION: Observe the instructions in the manual<\/figcaption><\/figure>\n<\/div>\n\n\n<figure class=\"wp-block-image is-resized\"><a href=\"https:\/\/knowledgebase.fischerpanda.de\/?attachment_id=491\" target=\"_blank\" rel=\"noreferrer noopener\"><img decoding=\"async\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/warning_r_general.gif\" alt=\"General warning\" class=\"wp-image-491\" width=\"81\" height=\"70\"\/><\/a><figcaption class=\"wp-element-caption\">General warning<\/figcaption><\/figure>\n\n\n\n<h4 class=\"clear wp-block-heading\">Causes and solutions<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Common causes<\/strong><\/td><td><strong>Possible solutions<\/strong><\/td><\/tr><tr><td>The connection from converter control PCB to the power electronics driver is not connected, defective, or has a loose contact.<\/td><td>Check the connection from converter control PCB to the power electronics driver for correct connection, defects and for loose contacts. <\/td><\/tr><tr><td>The connection from power electronics driver to the IGBT or MOSFET is not connected, defective or has a loose contact.<\/td><td>Check the connection from power electronics driver to the IGBT or MOSFET for correct connection, defects and for loose contacts. <\/td><\/tr><tr><td>A high voltage or high current event on the power side occurred, which is detected by the power electronics driver.<\/td><td>Contact the Fischer Panda Service.<\/td><\/tr><tr><td>Wrong parameters are set in the power converter control function.<\/td><td>Check the parameters in the power converter control function for correct values.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity clear is-style-dots\"\/>\n\n\n\n<h4 class=\"clear wp-block-heading\">Distributors and Services<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">For any service or maintenance questions, please contact Fischer Panda or our <a rel=\"noreferrer noopener\" aria-label=\" (opens in a new tab)\" href=\"https:\/\/www.fischerpanda.de\/distributors-and-services.htm\" target=\"_blank\">worldwide partners<\/a>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n","protected":false},"excerpt":{"rendered":"<p>An error on the power switch (IGBT\/MOSFET) or in the power switch driver electronic was detected.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[26],"tags":[],"class_list":["post-5557","post","type-post","status-publish","format-standard","hentry","category-event-codes","entry"],"acf":[],"_links":{"self":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/5557","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5557"}],"version-history":[{"count":2,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/5557\/revisions"}],"predecessor-version":[{"id":6289,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/5557\/revisions\/6289"}],"wp:attachment":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5557"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=5557"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=5557"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}