{"id":4073,"date":"2020-10-02T09:19:24","date_gmt":"2020-10-02T07:19:24","guid":{"rendered":"https:\/\/knowledgebase.fischerpanda.de\/?p=4073"},"modified":"2021-06-02T15:09:31","modified_gmt":"2021-06-02T13:09:31","slug":"the-fpcontrol-cooldown-phase","status":"publish","type":"post","link":"https:\/\/knowledgebase.fischerpanda.de\/?p=4073","title":{"rendered":"The fpControl cooldown phase"},"content":{"rendered":"\n<h3 class=\"h3-weiss-blau wp-block-heading\">Introduction to the topic<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The <a href=\"https:\/\/knowledgebase.fischerpanda.de\/?p=3762\" target=\"_blank\" rel=\"noreferrer noopener\">\u00bbfpControl GC-S\u00ab<\/a> has an integrated cooldown phase to cool the engine down before it is switched off. All generators with fpControl have this feature. The duration of the cooldown phase can be set in the service menu of the <a href=\"https:\/\/knowledgebase.fischerpanda.de\/?p=3780\" target=\"_blank\" rel=\"noreferrer noopener\">\u00bbfpControl CP-G\u00ab<\/a>. So the cool down phase can be adapted to individual applications. <\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Software Requirements<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>\u00bbfpControl Generator Control &#8211; Servo\u00ab (fpControl GC-S): <strong>V000R11 or higher<\/strong> <\/li><li>\u00bbfpControl Control Panel &#8211; Generator\u00ab (fpControl CP-G): <strong>V005R02 or higher<\/strong><\/li><\/ul>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Configuration<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">You can configure the cooldown phase to adapt the function to different requirements. <\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>You can activate and deactivate the cooldown phase.<\/li><li>You can set the duration of the cooldown phase.<\/li><\/ul>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Requirement<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">For the configuration of the cooldown phase you must enter the service password or have admin rights while the function is being called.<\/p>\n\n\n\n<h4 class=\"h4-grey-background wp-block-heading\">Activating and deactivating the cooldown phase <\/h4>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Function call<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>service<\/strong> &gt; <strong>enter service-code<\/strong> &gt; <strong>cooldown phase &gt; turn on \/ off<\/strong> <\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Step by step guide<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li>Open menu \u00bbservice\u00ab.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/09\/main-menu-service.jpg\" alt=\"\" class=\"wp-image-3876\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Enter the service password.<\/li><li>Select \u00bbcooldown phase\u00ab.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/10\/cooldown_phase.jpg\" alt=\"\" class=\"wp-image-4081\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Select \u00bbturn on \/ off\u00ab.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/10\/cooldown_turn_on_off.jpg\" alt=\"\" class=\"wp-image-4079\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Select \u00bbon\u00ab and confirm.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/10\/cooldown_on.jpg\" alt=\"\" class=\"wp-image-4080\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Select \u00bbconfirm\u00ab.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/confirm-frame.jpg\" alt=\"\" class=\"wp-image-3555\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Result:<\/strong> The cooldown phase is activated. Now you can set the Duration.<\/p>\n\n\n\n<h4 class=\"h4-grey-background wp-block-heading\">Setting the duration of the cooldown phase <\/h4>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Function call<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>service<\/strong> &gt; <strong>enter service-code<\/strong> &gt; <strong>cooldown phase &gt; time<\/strong> <\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Step by step guide<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li>Select \u00bbtime\u00ab.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/10\/cooldown_time.jpg\" alt=\"\" class=\"wp-image-4082\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Set the duration of the cooldown phase using the arrow keys and confirm. The duration in [s] can be set between 0&nbsp;s and 300&nbsp;s in 1&nbsp;s increments.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/10\/cooldown_time_value.jpg\" alt=\"\" class=\"wp-image-4083\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Select \u00bbconfirm\u00ab.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/confirm-frame.jpg\" alt=\"\" class=\"wp-image-3555\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Result:<\/strong> The duration of the cooldown phase has been set to the needed time.<\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Frequently asked questions<\/h3>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">How long is the cooldown phase? <\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">The duration of the cooldown phase can be set in the service menu of the \u00bbfpControl CP-G\u00ab. <\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Does the duration of the cooldown phase depend on the engine temperature?<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">No, the duration of the cooldown phase does not depend on the temperature. The cooldown phase always corresponds to the duration set in the service menu. <\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">How can the cooldown phase be canceled if, for example, a dangerous situation occurs during this duration?<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">By pressing the start \/ stop button again, the cooldown phase is canceled and the generator stops.<\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">At what rotation speed does the generator run in the cooldown phase? <\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">During the cooldown phase, the servomotor is in its idle position, which determines the rotation speed. The idle position of the servomotor is determined by the generator type. With the AGT, the speed corresponds to the nominal battery voltage. <\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Can the rotation speed at which the generator runs during the cooldown phase be set?  <\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">No, the rotation speed during the cooldown phase is determined depending on the generator type. Only the duration of the cooldown phase can be set. <\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Do AC generators with fpControl also have a cool down phase?  <\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Yes, this feature is available for all generators with fpControl. <\/p>\n\n\n\n<table class=\"wp-block-table aligncenter is-style-regular\"><tbody><tr><td><strong>NOTICE<\/strong><\/td><\/tr><tr><td><strong>With AC generators, the frequency and voltage are not within their limit values during the cooldown phase.<\/strong><br> \u25ba Activate the cooldown phase for AC generators only with a load contactor at the output. <\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n","protected":false},"excerpt":{"rendered":"<p>The \u00bbfpControl GC-S\u00ab has an integrated cooldown phase to cool the engine down before it is switched off. All generators with fpControl have this feature. The duration of the cooldown phase can be set in the service menu of the \u00bbfpControl CP-G\u00ab. So the cool down phase can be adapted to individual applications. <\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[30,42,22],"tags":[],"class_list":["post-4073","post","type-post","status-publish","format-standard","hentry","category-app-notes-fpcontrol","category-cooldown-phase","category-fpcontrol","entry"],"acf":[],"_links":{"self":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/4073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4073"}],"version-history":[{"count":10,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/4073\/revisions"}],"predecessor-version":[{"id":4171,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/4073\/revisions\/4171"}],"wp:attachment":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4073"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=4073"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=4073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}