{"id":3804,"date":"2020-08-28T17:05:20","date_gmt":"2020-08-28T15:05:20","guid":{"rendered":"https:\/\/knowledgebase.fischerpanda.de\/?p=3804"},"modified":"2021-08-16T10:09:18","modified_gmt":"2021-08-16T08:09:18","slug":"fpcontrol-measurement-unit-mu-3ph-dc","status":"publish","type":"post","link":"https:\/\/knowledgebase.fischerpanda.de\/?p=3804","title":{"rendered":"Datasheet \u00bbfpControl Measurement Unit &#8211; MU-3ph\/DC\u00ab"},"content":{"rendered":"\n<h3 class=\"h3-weiss-blau wp-block-heading\">Application<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The \u00bbfpControl Measurement Unit &#8211; MU-3ph \/ DC\u00ab is used for AC and DC generators. <\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Product description<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">On AC generators, the module measures the AC voltage up to 400 V in three phases and the AC current three times via an external sensor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When used on DC generators, the module measures the DC voltage in two phases in the range from 12 V to 600 V and twice the DC current via an external sensor.<\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Connectors<\/h3>\n\n\n\n<figure class=\"wp-block-image is-resized\"><img decoding=\"async\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fp1901-connectors-1024x614.jpg\" alt=\"Connectors of the \u00bbfpControl Measurement Unit - MU-3ph\/DC\u00ab (fpControl MU-3ph\/DC) \" class=\"wp-image-4475\" width=\"768\" height=\"461\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fp1901-connectors-1024x614.jpg 1024w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fp1901-connectors-300x180.jpg 300w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fp1901-connectors-768x460.jpg 768w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fp1901-connectors.jpg 1278w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><figcaption> <em>Connectors of the<\/em> <em>\u00bbfpControl Measurement Unit &#8211; MU-3ph\/DC\u00ab (fpControl MU-3ph\/DC)<\/em> <\/figcaption><\/figure>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td>X202<\/td><td>USB<\/td><\/tr><tr><td><a href=\"#x212\">X212<\/a><\/td><td>Boost relay<\/td><\/tr><tr><td>X203<\/td><td>Temperature sensor \u00bbTEMP 2\u00ab <\/td><\/tr><tr><td>X204<\/td><td>Temperature sensor \u00bbTEMP 3\u00ab <\/td><\/tr><tr><td><a href=\"#x207\">X207<\/a><\/td><td>external current transformer L3 \u00bbI L3\u00ab<\/td><\/tr><tr><td><a href=\"#x102\">X102<\/a><\/td><td>DC voltage measurement (0\u202669 V DC) 3 x (+), 1 x (-) <\/td><\/tr><tr><td><a href=\"#x101\">X101<\/a><\/td><td><strong>AC:<\/strong> voltage measurement L1, L2, L3 and N (0\u2026400 V ~ RMS) and PE <strong>or<\/strong><br><strong>DC:<\/strong> 3 x (+), 1 x (-), 1 x PE (669 V DC)  <\/td><\/tr><tr><td><a href=\"#x206\">X206<\/a><\/td><td>external current transformer L2 \u00bbI L2\u00ab<\/td><\/tr><tr><td><a href=\"#x205\">X205<\/a><\/td><td>external current transformer L1 \u00bbI L1\u00ab <\/td><\/tr><tr><td>X201<\/td><td>Temperature sensor \u00bbTEMP 1\u00ab <\/td><\/tr><tr><td><a href=\"#x213\">X213<\/a><\/td><td>AUX<\/td><\/tr><tr><td><a href=\"#x209\">X209<\/a><\/td><td>Alternative for the external fpCAN (USER CAN BUS)<\/td><\/tr><tr><td><a href=\"#x210_x211\">X210<\/a><\/td><td>Supply voltage and \u00bbfpCAN\u00ab<\/td><\/tr><tr><td><a href=\"#x210_x211\">X211<\/a><\/td><td>Supply voltage and \u00bbfpCAN\u00ab<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Pin assignments <\/h3>\n\n\n\n<h5 id=\"x212\" class=\"h5-grey-background wp-block-heading\">Pin assignment of \u00bbX212\u00ab for the boost relay<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">2-pin Phoenix Contact socket \/ plug with push-in spring cage connection terminals.  <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Pin<\/strong><\/td><td><strong>Label<\/strong><\/td><td><strong>Line<\/strong><\/td><\/tr><tr><td>1<\/td><td>BOOST +<\/td><td>Output boost relay<\/td><\/tr><tr><td>2<\/td><td>BOOST &#8211;<\/td><td>GND boost relay<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h5 id=\"x207\" class=\"h5-grey-background wp-block-heading\">Pin assignment of \u00bbX207\u00ab for the external current transformer L3 \u00bbI L3\u00ab<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">3-pin Phoenix Contact socket \/ plug with push-in spring cage connection terminals.  <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Pin<\/strong><\/td><td><strong>Label<\/strong><\/td><td><strong>Line<\/strong><\/td><\/tr><tr><td>1<\/td><td>+<\/td><td>+5 V supply<\/td><\/tr><tr><td>2<\/td><td>IL3<\/td><td>Sensor output<\/td><\/tr><tr><td>3<\/td><td>&#8211;<\/td><td>GND<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h5 id=\"x102\" class=\"h5-grey-background wp-block-heading\">Pin assignment of \u00bbX102\u00ab for DC voltage measurement<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li>DC voltage measurement (0\u202669 V DC) 3 x (+), 1 x (-).<\/li><li>4-pin Phoenix Contact socket \/ plug with push-in spring cage connection terminals.<\/li><\/ul>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Pin<\/strong><\/td><td><strong>Line<\/strong><\/td><\/tr><tr><td>1<\/td><td>+<\/td><\/tr><tr><td>2<\/td><td>+<\/td><\/tr><tr><td>3<\/td><td>+<\/td><\/tr><tr><td>4<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h5 id=\"x101\" class=\"h5-grey-background wp-block-heading\">Pin assignment of \u00bbX101\u00ab for AC \/ DC voltage measurement<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">5-pin Phoenix Contact socket \/ plug with push-in spring cage connection terminals.  <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Pin<\/strong><\/td><td><strong>Label<\/strong><\/td><td><strong>Line<\/strong><\/td><\/tr><tr><td>1<\/td><td>L1 (+)<\/td><td>L1<\/td><\/tr><tr><td>2<\/td><td>L2 (+)<\/td><td>L2<\/td><\/tr><tr><td>3<\/td><td>L3 (+)<\/td><td>L3<\/td><\/tr><tr><td>4<\/td><td>N (-)<\/td><td>N<\/td><\/tr><tr><td>5<\/td><td>PE<\/td><td>PE<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h5 id=\"x206\" class=\"h5-grey-background wp-block-heading\">Pin assignment of \u00bbX206\u00ab for the external current transformer L2 \u00bbI L2\u00ab<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">3-pin Phoenix Contact socket \/ plug with push-in spring cage connection terminals.  <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Pin<\/strong><\/td><td><strong>Label<\/strong><\/td><td><strong>Line<\/strong><\/td><\/tr><tr><td>1<\/td><td>+<\/td><td>+5 V supply<\/td><\/tr><tr><td>2<\/td><td>IL2<\/td><td>Sensor output<\/td><\/tr><tr><td>3<\/td><td>&#8211;<\/td><td>GND<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h5 id=\"x205\" class=\"h5-grey-background wp-block-heading\">Pin assignment of \u00bbX205\u00ab for the external current transformer L1 \u00bbI L1\u00ab<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">3-pin Phoenix Contact socket \/ plug with push-in spring cage connection terminals.  <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Pin<\/strong><\/td><td><strong>Label<\/strong><\/td><td><strong>Line<\/strong><\/td><\/tr><tr><td>1<\/td><td>+<\/td><td>+5 V supply<\/td><\/tr><tr><td>2<\/td><td>IL1<\/td><td>Sensor output<\/td><\/tr><tr><td>3<\/td><td>&#8211;<\/td><td>GND<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h5 id=\"x213\" class=\"h5-grey-background wp-block-heading\">Pin assignment of \u00bbX213\u00ab for \u00bbAUX\u00ab<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">2-pin Phoenix Contact socket \/ plug with push-in spring cage connection terminals.  <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Pin<\/strong><\/td><td><strong>Line<\/strong><\/td><\/tr><tr><td>1<\/td><td>AUX (+)<\/td><\/tr><tr><td>2<\/td><td>AUX (-)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h5 id=\"x209\" class=\"h5-grey-background wp-block-heading\">Pin assignment of \u00bbX209\u00ab, alternative for the external \u00bbfpCAN\u00ab <\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">4-pin Phoenix Contact socket \/ plug with push-in spring cage connection terminals.  <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Pin<\/strong><\/td><td><strong>Label<\/strong><\/td><td><strong>Line<\/strong><\/td><\/tr><tr><td>1<\/td><td>&#8211;<\/td><td>GND<\/td><\/tr><tr><td>2<\/td><td>H<\/td><td>CAN high<\/td><\/tr><tr><td>3<\/td><td>L<\/td><td>CAN low<\/td><\/tr><tr><td>4<\/td><td>+<\/td><td>Bus power<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h5 id=\"x210_x211\" class=\"h5-grey-background wp-block-heading\">Pin assignment of \u00bbX210\u00ab and \u00bbX211\u00ab for supply voltage and \u00bbfpCAN\u00ab<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">RJ45 socket, Label \u00bbFP-CAN\u00ab.  <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note<\/strong>: Bus termination is required if the \u00bbfpControl MU-3ph\/DC\u00ab is the last module in the \u00bbfpCAN\u00ab.  <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Pin<\/strong><\/td><td><strong>Line<\/strong><\/td><\/tr><tr><td>1<\/td><td>CAN high<\/td><\/tr><tr><td>2<\/td><td>CAN low<\/td><\/tr><tr><td>3<\/td><td>GND<\/td><\/tr><tr><td>4<\/td><td>Wake up<\/td><\/tr><tr><td>5<\/td><td>Bus power<\/td><\/tr><tr><td>6<\/td><td>GND<\/td><\/tr><tr><td>7<\/td><td>GND<\/td><\/tr><tr><td>8<\/td><td>Bus power<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Environmental specifications and physical data <\/h3>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td>Storage temperature<\/td><td>-30 \u00b0C \u2013 +60 \u00b0C<\/td><\/tr><tr><td>Operating temperature<\/td><td>-20 \u00b0C \u2013 +50 \u00b0C<\/td><\/tr><tr><td>Supply voltage<\/td><td>12 V oder 24 V, Automotive (12\u201313,5 V oder 24\u201328 V)<\/td><\/tr><tr><td>Rated current consumption<\/td><td>&lt; 139 mA @ 12 V<br>&lt; 91 mA @ 24 V<\/td><\/tr><tr><td>Housing<\/td><td>&#8212;<\/td><\/tr><tr><td>Protection class<\/td><td>IP30<\/td><\/tr><tr><td>Overall dimensions<\/td><td>114 mm x 72,5 mm (L x B) (Printed circuit board)<\/td><\/tr><tr><td>Weight<\/td><td>0,094 kg (Printed circuit board)<\/td><\/tr><tr><td>FP part number<\/td><td>0029859<\/td><\/tr><tr><td>Printed circuit board<\/td><td>FP1901<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Accessories <\/h3>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">\u00bbfpCAN\u00ab patch cable<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Available in different length. With a data transfer rate of 250 kbps and up to 30 nodes, the maximum cable length is 40 meters. <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Length<\/strong><\/td><td><strong>Fischer Panda part number<\/strong><\/td><\/tr><tr><td>25 m<\/td><td>0013474<\/td><\/tr><tr><td>15 m<\/td><td>0004686<\/td><\/tr><tr><td>10 m<\/td><td>0013473<\/td><\/tr><tr><td>6 m<\/td><td>0013472<\/td><\/tr><tr><td>3 m<\/td><td>0013471<\/td><\/tr><tr><td>1 m<\/td><td>0013470<\/td><\/tr><tr><td>0,5 m<\/td><td>0013468<\/td><\/tr><tr><td>0,2 m<\/td><td>0013466<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Terminating resistor<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">The ends of the \u00bbfpCAN\u00ab network must be terminated with a 120 ohm resistor. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00bbfpCAN\u00ab terminating resistor 120 Ohm with RJ45 connector, red RAL 3000 with FP logo. Fischer Panda part number 0003022.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-1024x878.jpg\" alt=\"fpCAN termination resistor 120 Ohm with RJ45 connector, red RAL 3000 with FP logo\" class=\"wp-image-3584\" width=\"256\" height=\"220\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-1024x878.jpg 1024w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-300x257.jpg 300w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-768x659.jpg 768w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-1568x1345.jpg 1568w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert.jpg 2046w\" sizes=\"(max-width: 256px) 100vw, 256px\" \/><\/figure><\/div>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n","protected":false},"excerpt":{"rendered":"<p>The \u00bbfpControl Measurement Unit &#8211; MU-3ph \/ DC\u00ab is used for AC and DC generators. <\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[22,56,28],"tags":[],"class_list":["post-3804","post","type-post","status-publish","format-standard","hentry","category-fpcontrol","category-measurement-unit","category-tech-datasheet-fpcontrol","entry"],"acf":[],"_links":{"self":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/3804","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3804"}],"version-history":[{"count":11,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/3804\/revisions"}],"predecessor-version":[{"id":5001,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/3804\/revisions\/5001"}],"wp:attachment":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3804"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3804"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3804"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}