{"id":3780,"date":"2020-08-28T17:08:18","date_gmt":"2020-08-28T15:08:18","guid":{"rendered":"https:\/\/knowledgebase.fischerpanda.de\/?p=3780"},"modified":"2021-06-07T12:20:20","modified_gmt":"2021-06-07T10:20:20","slug":"fpcontrol-control-panel-generator","status":"publish","type":"post","link":"https:\/\/knowledgebase.fischerpanda.de\/?p=3780","title":{"rendered":"Datasheet \u00bbfpControl Control Panel &#8211; Generator\u00ab"},"content":{"rendered":"\n<h3 class=\"h3-weiss-blau wp-block-heading\">Application<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The \u00bbfpControl Control Panel &#8211; Generator\u00ab (fpControl CP-G) is intended for use on generators with xControl or <a href=\"https:\/\/knowledgebase.fischerpanda.de\/?p=3756\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\"fpControl system (opens in a new tab)\">fpControl system<\/a>. It is the user interface of the control system and is used to operate and display system data. In addition, parameters can be set in the service area.<\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Product description<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Automatic start contact to start and stop the generator in addition to the start \/ stop button. <\/li><li>Operating temperature range from -20 \u00b0C to +50 \u00b0C. <\/li><li>Display resolution: 128 x 64 pixels.<\/li><li>Integrated display heater.  <\/li><li>Integrated buzzer for the acoustic output of warnings and errors.<\/li><li>Each \u00bbfpControl CP-G\u00ab can also be used as a slave panel and as an update panel for <a href=\"https:\/\/knowledgebase.fischerpanda.de\/?p=3377\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\"software update (opens in a new tab)\">software update<\/a>.<\/li><li>When used as an update panel, the \u00bbfpControl CP-G\u00ab works like a USB removable storage device on which the update files for all updateable system components can be stored. <\/li><li>Several slave panels can be used in one system.<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fpControl-Running-freigestellt_web.jpg\" alt=\"\u00bbfpControl Control Panel - Generator\u00ab (fpControl CP-G)\" class=\"wp-image-3782\" width=\"450\" height=\"241\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fpControl-Running-freigestellt_web.jpg 600w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fpControl-Running-freigestellt_web-300x161.jpg 300w\" sizes=\"(max-width: 450px) 100vw, 450px\" \/><figcaption><em>\u00bbfpControl Control Panel &#8211; Generator\u00ab (fpControl C<\/em>P-G)<\/figcaption><\/figure><\/div>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Controls<\/h3>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Button Symbol<\/strong><\/td><td><strong>Function<\/strong><\/td><\/tr><tr><td><img decoding=\"async\" width=\"71\" height=\"71\" class=\"wp-image-3787\" style=\"width: 71px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/button-on-off-71px.jpg\"><\/td><td>on \/ off<\/td><\/tr><tr><td><img decoding=\"async\" width=\"71\" height=\"71\" class=\"wp-image-3016\" style=\"width: 71px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/11\/fpControl-arrow-up-10mm.jpg\"><\/td><td>up<\/td><\/tr><tr><td><img decoding=\"async\" width=\"71\" height=\"71\" class=\"wp-image-3015\" style=\"width: 71px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/11\/fpControl-arrow-down-10mm.jpg\"><\/td><td>down<\/td><\/tr><tr><td><img decoding=\"async\" width=\"71\" height=\"71\" class=\"wp-image-3014\" style=\"width: 71px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/11\/fpControl-start-stop-10mm.jpg\"><\/td><td>start \/ stop<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Connectors<\/h3>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fpControl-CP-G-Connectors-labels.jpg\" alt=\"Connectors of the \u00bbfpControl CP-G\u00ab\" class=\"wp-image-4378\" width=\"392\" height=\"496\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fpControl-CP-G-Connectors-labels.jpg 523w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fpControl-CP-G-Connectors-labels-237x300.jpg 237w\" sizes=\"(max-width: 392px) 100vw, 392px\" \/><figcaption><em>Connectors of the \u00bbfpControl CP-G\u00ab<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Connector<\/strong><\/td><td><strong>Assignment<\/strong><\/td><\/tr><tr><td>X3<\/td><td>Removable disk for update files (USB)<\/td><\/tr><tr><td>X103<\/td><td>Supply voltage and <a href=\"https:\/\/knowledgebase.fischerpanda.de\/?p=3817\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\"\u00bbfpCAN\u00ab (opens in a new tab)\">\u00bbfpCAN\u00ab<\/a><\/td><\/tr><tr><td>X102<\/td><td>Supply voltage and \u00bbfpCAN\u00ab<\/td><\/tr><tr><td>X101<\/td><td>Automatic start contact<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Pin assignments<\/h3>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Pin assignment of \u00bbX103\u00ab and \u00bbX102\u00ab for supply voltage and \u00bbfpCAN\u00ab<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">RJ45 socket.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note<\/strong>: <a href=\"#terminating_resistor\">Bus termination<\/a> is required if the \u00bbfpControl CP-G\u00ab is the last module in the \u00bbfpCAN\u00ab. <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Pin<\/strong><\/td><td><strong>Line<\/strong><\/td><\/tr><tr><td>1<\/td><td>CAN high<\/td><\/tr><tr><td>2<\/td><td>CAN low<\/td><\/tr><tr><td>3<\/td><td>GND<\/td><\/tr><tr><td>4<\/td><td>Wake up<\/td><\/tr><tr><td>5<\/td><td>Bus power<\/td><\/tr><tr><td>6<\/td><td>GND<\/td><\/tr><tr><td>7<\/td><td>GND<\/td><\/tr><tr><td>8<\/td><td>Bus power<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Environmental specifications and physical data<\/h3>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td>Storage temperature<\/td><td>-10 \u00b0C \u2013 +60 \u00b0C<\/td><\/tr><tr><td>Operating temperature<\/td><td>-20 \u00b0C \u2013 +50 \u00b0C<\/td><\/tr><tr><td>Supply voltage<\/td><td>12 V oder 24 V, Automotive (12\u201313,5 V oder 24\u201328 V)<\/td><\/tr><tr><td>Rated current consumption<\/td><td>&lt; 21 mA @ 12 V (without display heating)<br>&lt; 18 mA @ 24 V (without display heating)<\/td><\/tr><tr><td>Max. current consumption<\/td><td>120 mA (including display heating)<\/td><\/tr><tr><td>Current consumption in standby mode \/ off<\/td><td>0 A<\/td><\/tr><tr><td>Housing<\/td><td>ABS plastic<\/td><\/tr><tr><td>Protection class<\/td><td>IP30 (plugged in RJ45 connector)<\/td><\/tr><tr><td>Overall dimensions<\/td><td>120 x 65 x 35 mm (L x B x H), <br>Cutout: 109,2 x 54,5 mm<\/td><\/tr><tr><td>Weight<\/td><td>0,11 kg<\/td><\/tr><tr><td>FP part number<\/td><td>0029338<\/td><\/tr><tr><td>Printed circuit board<\/td><td>FP1403<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Accessories<\/h3>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">fpCAN patch cable<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Available in different length. With a data transfer rate of 250 kbps and up to 30 nodes, the maximum cable length is 40 meters.  <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Length<\/strong><\/td><td><strong>Fischer Panda part number<\/strong><\/td><\/tr><tr><td>25 m<\/td><td>0013474<\/td><\/tr><tr><td>15 m<\/td><td>0004686<\/td><\/tr><tr><td>10 m<\/td><td>0013473<\/td><\/tr><tr><td>6 m<\/td><td>0013472<\/td><\/tr><tr><td>3 m<\/td><td>0013471<\/td><\/tr><tr><td>1 m<\/td><td>0013470<\/td><\/tr><tr><td>0,5 m<\/td><td>0013468<\/td><\/tr><tr><td>0,2 m<\/td><td>0013466<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h5 id=\"terminating_resistor\" class=\"h5-grey-background wp-block-heading\">Terminating resistor<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">The ends of the \u00bbfpCAN\u00ab network must be terminated with a 120 ohm resistor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00bbfpCAN\u00ab terminating resistor 120 Ohm with RJ45 connector, red RAL 3000 with FP logo. Fischer Panda part number 0003022.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-1024x878.jpg\" alt=\"fpCAN termination resistor 120 Ohm with RJ45 connector, red RAL 3000 with FP logo\" class=\"wp-image-3584\" width=\"256\" height=\"220\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-1024x878.jpg 1024w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-300x257.jpg 300w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-768x659.jpg 768w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-1568x1345.jpg 1568w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert.jpg 2046w\" sizes=\"(max-width: 256px) 100vw, 256px\" \/><\/figure><\/div>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n","protected":false},"excerpt":{"rendered":"<p>The \u00bbfpControl Control Panel &#8211; Generator\u00ab (fpControl CP-G) is intended for use on generators with xControl or fpControl system. It is the user interface of the control system and is used to operate and display system data. In addition, parameters can be set in the service area.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[54,22,28],"tags":[],"class_list":["post-3780","post","type-post","status-publish","format-standard","hentry","category-control-panel","category-fpcontrol","category-tech-datasheet-fpcontrol","entry"],"acf":[],"_links":{"self":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/3780","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3780"}],"version-history":[{"count":12,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/3780\/revisions"}],"predecessor-version":[{"id":4489,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/3780\/revisions\/4489"}],"wp:attachment":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3780"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3780"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3780"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}