{"id":3454,"date":"2020-05-06T13:06:14","date_gmt":"2020-05-06T11:06:14","guid":{"rendered":"https:\/\/knowledgebase.fischerpanda.de\/?p=3454"},"modified":"2021-09-06T15:18:19","modified_gmt":"2021-09-06T13:18:19","slug":"communication-interface-nmea-2000","status":"publish","type":"post","link":"https:\/\/knowledgebase.fischerpanda.de\/?p=3454","title":{"rendered":"Communication Interface CI &#8211; NMEA 2000\u00ae"},"content":{"rendered":"\n<h3 class=\"h3-weiss-blau wp-block-heading\">Introduction to the topic<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The \u00bbCommunication Interface CI &#8211; NMEA 2000\u00ae\u00ab is a gateway for integrating <a aria-label=\" (opens in a new tab)\" rel=\"noreferrer noopener\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?page_id=3482\" target=\"_blank\">fpCAN<\/a>-equipped Fischer Panda AC Generators with an NMEA 2000\u00ae network. The \u00bbCommunication Interface CI &#8211; NMEA 2000\u00ae\u00ab converts fpCAN messages to NMEA 2000\u00ae messages so you can monitor your Fischer Panda AC Generator with NMEA 2000\u00ae displays. The \u00bbCommunication Interface CI &#8211; NMEA 2000\u00ae\u00ab is certified by <a aria-label=\" (opens in a new tab)\" rel=\"noreferrer noopener\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?page_id=3482\" target=\"_blank\">NMEA<\/a> 2000\u00ae (<a aria-label=\"https:\/\/www.nmea.org (opens in a new tab)\" rel=\"noreferrer noopener\" href=\"https:\/\/www.nmea.org\" target=\"_blank\">https:\/\/www.nmea.org<\/a>).   <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/NMEA_Interface_1-1024x934.jpg\" alt=\"Communication Interface CI - NMEA 2000\" class=\"wp-image-3469\" width=\"512\" height=\"467\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/NMEA_Interface_1-1024x934.jpg 1024w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/NMEA_Interface_1-300x274.jpg 300w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/NMEA_Interface_1-768x701.jpg 768w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/NMEA_Interface_1-1568x1431.jpg 1568w\" sizes=\"(max-width: 512px) 100vw, 512px\" \/><figcaption> <em>Fischer Panda \u00bbCommunication Interface CI &#8211; NMEA 2000\u00ae\u00ab <\/em><\/figcaption><\/figure><\/div>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Frequenly asked questions <\/h3>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Which NMEA 2000\u00ae <a aria-label=\" (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?page_id=3482\" target=\"_blank\" rel=\"noreferrer noopener\">PGNs<\/a> are supported?<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>NMEA 2000\u00ae Name<\/td><td>NMEA 2000\u00ae PGN #<\/td><\/tr><tr><td>ISO Acknowledgement <\/td><td>059392 <\/td><\/tr><tr><td>ISO Request<\/td><td>059904 <\/td><\/tr><tr><td>ISO Transport Protocol, Data Transfer<\/td><td>060160<\/td><\/tr><tr><td>ISO Transport Protocol, Conn. Management<\/td><td>060416<\/td><\/tr><tr><td>ISO Address Claim<\/td><td>060928 <\/td><\/tr><tr><td>ISO Commanded Address<\/td><td>065240 <\/td><\/tr><tr><td>ISO Software Version<\/td><td>065242<\/td><\/tr><tr><td>NMEA Request \/ Command \/ Acknowledge<\/td><td>126208<\/td><\/tr><tr><td>PGN List (Transmit and Receive)<\/td><td>126464<\/td><\/tr><tr><td>Heartbeat<\/td><td>126993<\/td><\/tr><tr><td>Product Information<\/td><td>126996<\/td><\/tr><tr><td>Configuration Information<\/td><td>126998<\/td><\/tr><tr><td>AC Output Status<\/td><td>127504<\/td><\/tr><tr><td>Engine Parameters, Rapid Update<\/td><td>127488<\/td><\/tr><tr><td>Engine Parameters, Dynamik<\/td><td>127489<\/td><\/tr><tr><td>AGS Configuration Status<\/td><td>127512<\/td><\/tr><tr><td>AGS Status<\/td><td>127514<\/td><\/tr><tr><td>AC Power \/ Current Phase A<\/td><td>127744<\/td><\/tr><tr><td>AC Power \/ Current Phase B <\/td><td>127745<\/td><\/tr><tr><td>AC Power \/ Current Phase C<\/td><td>127746<\/td><\/tr><tr><td>AC Voltage \/ Frequency Phase A<\/td><td>127747<\/td><\/tr><tr><td>AC Voltage \/ Frequency Phase B <\/td><td>127748<\/td><\/tr><tr><td>AC Voltage \/ Frequency Phase C<\/td><td>127749<\/td><\/tr><tr><td>DC Voltage \/ Current<\/td><td>127751<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A detailed documentation of the NMEA 2000\u00ae PGNs has to be bought from the NMEA website. <\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Which J1939 PGNs are supported?<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>J1939 PGN Name<\/td><td>J1939 PGN #<\/td><\/tr><tr><td>EEC1, Electronic Engine Controller #1<\/td><td>61444<\/td><\/tr><tr><td>GTACPP, Generator Total AC Percent Power<\/td><td>64911<\/td><\/tr><tr><td>GPCACR, Generator Phase C AC Reactive Power<\/td><td>65019<\/td><\/tr><tr><td>GPCACP, Generator Phase C AC Power<\/td><td>65020<\/td><\/tr><tr><td>GPCAC, Generator Phase C Basic AC Quantities<\/td><td>65021<\/td><\/tr><tr><td>GPBACRP, Generator Phase B AC Reactive Power<\/td><td>65022<\/td><\/tr><tr><td>GPBACP, Generator Phase B AC Power<\/td><td>65023<\/td><\/tr><tr><td>GPBAC, Generator Phase B Basic AC Quantities<\/td><td>65024<\/td><\/tr><tr><td>GPAACR, Generator Phase A AC Reactive Power<\/td><td>65025<\/td><\/tr><tr><td>GPAACP, Generator Phase A AC Power<\/td><td>65026<\/td><\/tr><tr><td>GPAAC, Generator Phase A Basic AC Quantities<\/td><td>65027<\/td><\/tr><tr><td>GAAC, Generator Average Basic AC Quantities<\/td><td>65030<\/td><\/tr><tr><td>HOURS, Engine Hours<\/td><td>65253<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A detailed documentation of the J1939 PGNs has to be bought from the SAE International website (SAE J1939-75 Generator Sets and Industrial Applications, <a aria-label=\"https:\/\/www.sae.org (opens in a new tab)\" href=\"https:\/\/www.sae.org\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.sae.org<\/a>). <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><img decoding=\"async\" width=\"56\" height=\"56\" class=\"wp-image-2536\" style=\"width: 56px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/information_sbu_transparent_52px.png\"><br>PGNs with data for phases B and C are only transmitted for 3-phase generators.<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">fpCAN <a aria-label=\" (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?page_id=3482\" target=\"_blank\" rel=\"noreferrer noopener\">SPNs<\/a> translated to NMEA 2000\u00ae PGNs<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">The table shows which SPNs \/ PGNs of the fpCAN are translated into which NMEA 2000\u00ae PGNs.<\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td>J1939 SPN\/PGN<\/td><td>Description<\/td><td>NMEA 2000\u00ae PGN<\/td><\/tr><tr><td>190 \/ 61444 <\/td><td>Engine Speed<\/td><td>127488<\/td><\/tr><tr><td>100 \/ 65263<\/td><td>Engine oil pressure<\/td><td>127489<\/td><\/tr><tr><td>110 \/ 65262<\/td><td>Engine coolant temperature<\/td><td>127489<\/td><\/tr><tr><td>175 \/ 65262<\/td><td>Engine oil temperature<\/td><td>127489<\/td><\/tr><tr><td>247 \/ 65253<\/td><td>Total engine hours<\/td><td>127489<\/td><\/tr><tr><td>513 \/ 61444<\/td><td>Percent engine\/inverter load<\/td><td>127489<\/td><\/tr><tr><td>520200 \/ 65281<\/td><td>System battery voltage<\/td><td>127489<\/td><\/tr><tr><td>2453 \/ 65026<\/td><td>Generator Phase A Real Power<\/td><td>127744<\/td><\/tr><tr><td>2449 \/ 65027<\/td><td>Generator Phase A AC RMS Current<\/td><td>127744<\/td><\/tr><tr><td>2454 \/ 65023<\/td><td>Generator Phase B Real Power <\/td><td>127745<\/td><\/tr><tr><td>2450 \/ 65024<\/td><td>Generator Phase B AC RMS Current <\/td><td>127745<\/td><\/tr><tr><td>2455 \/ 65020<\/td><td>Generator Phase C Real Power <\/td><td>127746<\/td><\/tr><tr><td>2451 \/ 65021<\/td><td>Generator Phase C AC RMS Current  <\/td><td>127746<\/td><\/tr><tr><td>2441 \/ 65027<\/td><td>Generator Phase AB Line to Line AC RMS Voltage<\/td><td>127747<\/td><\/tr><tr><td>2445 \/ 65027<\/td><td>Generator Phase A Line to Neutral AC RMS Voltage <\/td><td>127747<\/td><\/tr><tr><td>2437 \/ 65027<\/td><td>Generator Phase A AC Frequency <\/td><td>127747<\/td><\/tr><tr><td>2442 \/ 65024<\/td><td>Generator Phase BC Line to Line AC RMS Voltage <\/td><td>127748<\/td><\/tr><tr><td>2446 \/ 65024<\/td><td>Generator Phase B Line to Neutral AC RMS Voltage <\/td><td>127748<\/td><\/tr><tr><td>2438 \/ 65024<\/td><td>Generator Phase B AC Frequency <\/td><td>127748<\/td><\/tr><tr><td>2443 \/ 65021<\/td><td>Generator Phase CA Line to Line AC RMS Voltage  <\/td><td>127749<\/td><\/tr><tr><td>2447 \/ 65021<\/td><td>Generator Phase C Line to Neutral AC RMS Voltage  <\/td><td>127749<\/td><\/tr><tr><td>2439 \/ 65021<\/td><td>Generator Phase C AC Frequency <\/td><td>127749<\/td><\/tr><\/tbody><\/table>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><img decoding=\"async\" width=\"56\" height=\"56\" class=\"wp-image-2536\" style=\"width: 56px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/information_sbu_transparent_52px.png\"><br>The PGN fields transmit all data available for the generator. So with some generators not all fields (SPNs) contain valid data, for example, for the oil pressure.<\/td><\/tr><\/tbody><\/table>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><img decoding=\"async\" width=\"56\" height=\"56\" class=\"wp-image-2536\" style=\"width: 56px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/information_sbu_transparent_52px.png\"><br>Different multifunction displays show different subsets of the transmitted data. The \u00bbCommunication Interface CI &#8211; NMEA 2000\u00ae\u00ab reports itself as an ac generator. Check your multifunction display concerning its supported PGNs.<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Which manufacturer code does Fischer Panda GmbH have?<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">The manufacturer code is <strong>785<\/strong> (<strong>0x311<\/strong> hexadecimal).<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Product Code, Class Code and Function Code of the \u00bbCommunication Interface CI &#8211; NMEA 2000\u00ae\u00ab<\/h5>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td>Product Code<\/td><td>5636<\/td><\/tr><tr><td>Class Code<\/td><td>35 &#8211; Electrical Generation<\/td><\/tr><tr><td>Function Code<\/td><td>151 &#8211; AC Generator<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Which Fischer Panda generators can be connected to the NMEA2000 network?<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">All Fischer Panda generators that come with <strong>xControl<\/strong>, <strong>iControl2<\/strong> or <strong>fpControl<\/strong> can be connected to an NMEA 2000\u00ae network.<\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">How to connect the \u00bbCommunication Interface CI &#8211; NMEA 2000\u00ae\u00ab? <\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Connect the Communication Interface with the five pin Micro-C male connector to the NMEA 2000\u00ae network. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/NMEA_Interface_9_ausschnitt-1024x580.jpg\" alt=\"\" class=\"wp-image-3468\" width=\"512\" height=\"290\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/NMEA_Interface_9_ausschnitt-1024x580.jpg 1024w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/NMEA_Interface_9_ausschnitt-300x170.jpg 300w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/NMEA_Interface_9_ausschnitt-768x435.jpg 768w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/NMEA_Interface_9_ausschnitt-1568x888.jpg 1568w\" sizes=\"(max-width: 512px) 100vw, 512px\" \/><figcaption><em>fpCAN to NMEA 2000\u00ae connector<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Can I change the NMEA Device Instance (ISO ECU Instance)? <\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Yes, you can change the NMEA device instance (ISO-ECU instance). Use the PGN 126208 to request the ISO address claim message PGN 60928. Specify the fields 3 and 4 in the request. For a detailed description, use the original documentation from the NMEA that has to be bought from the NMEA website. <\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Is it possible to switch the generator on and off via NMEA 2000\u00ae? <\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Use the PGN 126208 to access the PGN 127512 (AGS Configuration Status) in command mode. Specify the field 3 in the request. For a detailed description, use the original documentation from the NMEA that has to be bought from the NMEA website.  <\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n","protected":false},"excerpt":{"rendered":"<p>The \u00bbCommunication Interface CI &#8211; NMEA 2000\u00ae\u00ab is a gateway for integrating fpCAN-equipped Fischer Panda generators with an NMEA 2000\u00ae network. The \u00bbCommunication Interface CI &#8211; NMEA 2000\u00ae\u00ab converts fpCAN messages to NMEA 2000\u00ae messages so you can monitor your Fischer Panda Generator with NMEA 2000\u00ae displays.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[7,22,18],"tags":[],"class_list":["post-3454","post","type-post","status-publish","format-standard","hentry","category-communication","category-fpcontrol","category-nmea-2000","entry"],"acf":[],"_links":{"self":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/3454","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3454"}],"version-history":[{"count":21,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/3454\/revisions"}],"predecessor-version":[{"id":5482,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/3454\/revisions\/5482"}],"wp:attachment":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3454"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3454"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3454"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}