{"id":3408,"date":"2020-04-30T22:07:00","date_gmt":"2020-04-30T20:07:00","guid":{"rendered":"https:\/\/knowledgebase.fischerpanda.de\/?p=3408"},"modified":"2021-06-07T10:06:14","modified_gmt":"2021-06-07T08:06:14","slug":"tank-sensor-for-fpcan","status":"publish","type":"post","link":"https:\/\/knowledgebase.fischerpanda.de\/?p=3408","title":{"rendered":"J1939 Tank sensor for \u00bbfpCAN\u00ab"},"content":{"rendered":"\n<table class=\"wp-block-table\"><tbody><tr><td><img decoding=\"async\" width=\"56\" height=\"56\" class=\"wp-image-2536\" style=\"width: 56px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/information_sbu_transparent_52px.png\"><br><strong>Note:<\/strong> This function is not available with every generator. Check in each individual case whether the function can be used with your generator.<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Introduction to the topic<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In order to monitor the level of the diesel fuel in the tank, you can integrate a tank sensor with <a aria-label=\" (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?page_id=3482\" target=\"_blank\" rel=\"noreferrer noopener\">SAE&nbsp;J1939<\/a>-CAN interface in the <a aria-label=\" (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?page_id=3482\" target=\"_blank\" rel=\"noreferrer noopener\">fpCAN<\/a>. The tank sensor sends the filling level of the diesel tank in percent on the <a aria-label=\" (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?page_id=3482\" target=\"_blank\" rel=\"noreferrer noopener\">CAN<\/a> bus.<\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Frequenly asked questions about using the tank sensor at the fpCAN<\/h3>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Which tank sensor does Fischer Panda approve for use on the fpCAN?<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li>ITS-60 Tank Sensor from <a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.bedia.com\" target=\"_blank\" rel=\"noreferrer noopener\">BEDIA Motorentechnik<\/a>. <br>A detailed product description is available on the manufacturer&#8217;s website at <a aria-label=\" (opens in a new tab)\" href=\"http:\/\/www.bedia.com\/index.php\/en\/products\/group\/its\/item\/product-bedia-its-60\" target=\"_blank\" rel=\"noreferrer noopener\">http:\/\/www.bedia.com\/index.php\/en\/products\/group\/its\/item\/product-bedia-its-60<\/a> <\/li><li>The catalog \u00bbBEDIA Intelligent Tank Sensors ITS 60\/65\u00ab can also be downloaded from this website. <\/li><\/ul>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">In which temperature range can I operate the tank sensor?<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li>The tank sensor has a working temperature range from -40\u202f\u00b0C bis +85\u202f\u00b0C.<\/li><\/ul>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Which measuring principle does the approved tank sensor use?<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li>The ITS-60 Tank Sensor uses a capacitive measuring principle and integrated electronics to determine the fill level.<\/li><li>The measurement works regardless of the diesel fuel used.<\/li><\/ul>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Is the tank sensor offered with different sensor pipe lengths?<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li>Fischer Panda offers the ITS-60 tank sensor in 4 standard sensor pipe lengths. <\/li><li>Further sensor pipe lengths are possible on request. <ul><li>minimal length: 200 mm <\/li><li>maximum length: 2300 mm <\/li><\/ul><\/li><\/ul>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td>Sensor pipe lenght<\/td><td>Measurement range start<\/td><td>Measurement range end<\/td><td>Fischer Panda article number<\/td><\/tr><tr><td>200 mm<\/td><td>190 mm<\/td><td>20 mm<\/td><td>0011625<\/td><\/tr><tr><td>470 mm<\/td><td>460 mm<\/td><td>20 mm<\/td><td>0027315<\/td><\/tr><tr><td>520 mm<\/td><td>510 mm<\/td><td>20 mm<\/td><td>0011626<\/td><\/tr><tr><td>590 mm<\/td><td>580 mm<\/td><td>20 mm<\/td><td>0025545<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">How is the tank sensor connected to the fpCAN and which adapters are required?<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li>The interface for connecting the ITS-60 tank sensor to the fpCAN is the \u00bbfpControl Connection Board &#8211; Generator\u00ab (fpControl <a aria-label=\" (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?page_id=3482\" target=\"_blank\" rel=\"noreferrer noopener\">CB-G<\/a>), which is located on the outside of the generator capsule.<\/li><li>You need two adapters to connect the tank sensor to the CB-G:<ul><li>One adapter \u00bbTank sensor-to-fpCAN\u00ab, which converts from Deutsch DT04-4P to the <a aria-label=\" (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?page_id=3482\" target=\"_blank\" rel=\"noreferrer noopener\">fpCAN patch cable<\/a> with RJ-45 connector.<\/li><li>A T-adapter that leads the generator panel cable and the adapter \u00bbTank sensor-to-fpCAN\u00ab to the RJ-45 socket of the CB-G.<\/li><\/ul><\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step by step guide<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Connect the Deutsch socket DT04-4P of the ITS-60 tank sensor with the Deutsch plug of the adapter \u00bbTank sensor-to-fpCAN\u00ab.<\/li><li>Connect the RJ-45 plug of the T-adapter to the RJ-45 socket of the \u00bbTank sensor-to-fpCAN\u00ab adapter.<\/li><li>Disconnect the generator panel cable from the CB-G.<\/li><li>Connect the generator panel cable to a free RJ-45 socket of the T-adapter.<\/li><li>Use an additional fpCAN patch cable to connect the free RJ-45 socket of the T-adapter to the RJ-45 socket of the \u00bbfpControl CB G\u00ab.<\/li><li><strong>Result:<\/strong> The ITS-60 Tank Sensor is connected to the fpCAN.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image is-resized\"><img decoding=\"async\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/Adapter-Tanksensor.png\" alt=\"\" class=\"wp-image-3446\" width=\"687\" height=\"458\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/Adapter-Tanksensor.png 916w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/Adapter-Tanksensor-300x200.png 300w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/Adapter-Tanksensor-768x512.png 768w\" sizes=\"(max-width: 687px) 100vw, 687px\" \/><\/figure>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td>1<\/td><td>adapter \u00bbTank sensor-to-fpCAN\u00ab, which converts from Deutsch DT04-4P to the fpCAN patch cable with RJ-45 connector<br><\/td><\/tr><tr><td>2<\/td><td>T-adapter that leads the generator panel cable and the adapter \u00bbTank sensor-to-fpCAN\u00ab to the RJ-45 socket of the CB-G<br><\/td><\/tr><tr><td>3<\/td><td>generator panel cable<\/td><\/tr><tr><td>4<\/td><td>additional fpCAN patch cable to connect the T-adapter to the RJ-45 socket of the \u00bbfpControl CB G\u00ab<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">How long is the connection cable of the tank sensor?<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li>The connection cable of the tank sensor has a length of 250 mm +\/- 15 mm (length specification including the Deutsch DT04-4P).<\/li><\/ul>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Can the tank sensor be used directly as a plug-and-play device?<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li>The sensor must be activated in the panel menu so that the filling level is displayed on the \u00bbxControl &#8211; <a aria-label=\" (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?page_id=3482\" target=\"_blank\" rel=\"noreferrer noopener\">CP-G<\/a>\u00ab \/ \u00bbfpControl CP-G\u00ab control panel.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step by step guide<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li> Open the \u00bbpanel\u00ab menu<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/04\/menu-panel-frame.jpg\" alt=\"\" class=\"wp-image-3414\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Select \u00bbopt. measured data\u00ab and confirm.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/04\/menu-opt-measured-data-frame.jpg\" alt=\"\" class=\"wp-image-3413\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Select \u00bbfuel-level\u00ab and confirm.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/04\/menu-fuel-level-frame.jpg\" alt=\"\" class=\"wp-image-3412\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Opportunities for action:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>You can select the \u00bbon\u00ab option. The filling level indicator is activated permanently.<\/li><li>You can select the \u00bbauto\u00ab option. The filling level is displayed when a tank sensor is detected in the fpCAN.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Continuation of the step by step guide<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Select one of the options \u00bbon\u00ab or \u00bbauto\u00ab and confirm.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/04\/fuel-level-auto-frame.jpg\" alt=\"\" class=\"wp-image-3410\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>Result:<\/strong> The tank sensor is activated.<\/li><li>The \u00bbxControl &#8211; CP-G\u00ab \/ \u00bbfpControl CP-G\u00ab displays the filling level in [%]:<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/04\/fuel-level-percent-frame.jpg\" alt=\"\" class=\"wp-image-3411\"\/><\/figure>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Which warning messages are possible when using a tank sensor?<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li>When the level of the diesel tank has reached the warning value, a warning is generated (event code 63). The \u00bbxControl &#8211; CP-G\u00ab \/ \u00bbfpControl CP-G\u00ab displays the warning with a pop-up window. <\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignleft\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/07\/event-63-warning-english.jpg\" alt=\"\" class=\"wp-image-1569\"\/><\/figure><\/div>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/07\/event-63-symbolic-warning.jpg\" alt=\"\" class=\"wp-image-1555\"\/><\/figure>\n\n\n\n<ul class=\"clear wp-block-list\"><li>If the option \u00bbon\u00ab is activated, a warning is generated (event code 149) if there is a problem with the bus communication or with the supply voltage of the tank sensor. The \u00bbxControl &#8211; CP-G\u00ab \/ \u00bbfpControl CP-G\u00ab displays the warning with a pop-up window. If the \u00bbauto\u00ab option is activated, there is no tank sensor warning. <\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignleft\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/04\/event-149-fuel-level-sensor-lost.jpg\" alt=\"\" class=\"wp-image-3415\"\/><\/figure><\/div>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/04\/event-149-fuel-level-sensor-lost-symbolic.jpg\" alt=\"\" class=\"wp-image-3417\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li> Here you can find detailed descriptions of <a aria-label=\"event 63 (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?p=908\" target=\"_blank\" rel=\"noreferrer noopener\">event 63<\/a> and <a aria-label=\"event 149 (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?p=1028\" target=\"_blank\" rel=\"noreferrer noopener\">event 149<\/a>.<\/li><\/ul>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\"> Can the warning value for the filling level be set on the control panel?<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li> Yes, the warning value for the filling level can be set on the control panel \u00bbxControl &#8211; CP-G\u00ab \/ \u00bbfpControl CP-G\u00ab. The default value for the warning is a filling level of 20%. You can set the warning value in 1% increments between the specified minimum and maximum value.<\/li><li>This feature is available from <strong>CP-G software release 5V02<\/strong>. <\/li><\/ul>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><img decoding=\"async\" width=\"56\" height=\"56\" class=\"wp-image-2536\" style=\"width: 56px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/information_sbu_transparent_52px.png\"><br>The warning value for the filling level can only be set if a tank sensor is connected to the fpCAN.<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step by step guide<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Open menu \u00bbgenerator\u00ab.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/menu-generator-frame.jpg\" alt=\"\" class=\"wp-image-3554\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Select option \u00bbfuel warn.-threshold\u00ab and confirm.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/fuel-level-warn-threshold-frame.jpg\" alt=\"\" class=\"wp-image-3556\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Set the warning value on the dialog page \u00bbfuel warn.-threshold\u00ab between the specified min and max value using the arrow keys of the panel.<\/li><li>Confirm the set warning value with the start \/ stop button.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/fuel-level-warn-threshold-percent-frame.jpg\" alt=\"\" class=\"wp-image-3557\"\/><\/figure>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Symbol<\/strong><\/td><td><strong>Function<\/strong><\/td><\/tr><tr><td><img decoding=\"async\" width=\"71\" height=\"71\" class=\"wp-image-3016\" style=\"width: 71px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/11\/fpControl-arrow-up-10mm.jpg\"><\/td><td>\u00bbIncrease warning value\u00ab key. A long press on the button activates the rapid increase of the warning value.<\/td><\/tr><tr><td><img decoding=\"async\" width=\"71\" height=\"71\" class=\"wp-image-3015\" style=\"width: 71px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/11\/fpControl-arrow-down-10mm.jpg\"><\/td><td>\u00bbDecrease warning value\u00ab key. A long press on the button activates the rapid decrease of the warning value.<\/td><\/tr><tr><td><img decoding=\"async\" width=\"71\" height=\"71\" class=\"wp-image-3014\" style=\"width: 71px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/11\/fpControl-start-stop-10mm.jpg\"><\/td><td>\u00bbConfirm warning value\u00ab key.<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Save the set warning value with \u00bbconfirm\u00ab and exit the dialog.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/confirm-frame.jpg\" alt=\"\" class=\"wp-image-3555\"\/><\/figure>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><img decoding=\"async\" width=\"56\" height=\"56\" class=\"wp-image-2536\" style=\"width: 56px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/information_sbu_transparent_52px.png\"><br>\u00bbcancel\u00ab lets you exit the dialog without saving the set warning value. The previous value is retained.<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\"> In which CAN message (PGN) is the fill level sent on the fpCAN?<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li><a aria-label=\" (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?page_id=3482\" target=\"_blank\" rel=\"noreferrer noopener\">PGN<\/a> 65276 (0xFEFC hexadecimal), symbol \u00bbDD1\u00ab (\u00bbDash Display\u00ab).<\/li><li><a aria-label=\" (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?page_id=3482\" target=\"_blank\" rel=\"noreferrer noopener\">SPN<\/a> 96<\/li><li>This PGN is sent in a 1000 ms cycle.<\/li><\/ul>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Can the tank sensor also be used on generators with iControl2?<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li>Yes, the tank sensor can also be used on generators with iControl2.<\/li><\/ul>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">What needs to be considered for generators with iControl2?<\/h5>\n\n\n\n<ul class=\"wp-block-list\"><li>The tank sensor must be connected to the fpCAN via the \u00bbfpControl CAN Interface &#8211; SAE J1939\u00ab (fpControl CI-SAE J1939) since no CB-G is available with the iGenerators.<\/li><li>The level measured by the tank sensor is only available as information on the fpCAN for iGenerators. The iControl2 panel does not show the filling level.<\/li><li>There is <strong>no low filling level warning<\/strong> on iGenerators.<\/li><\/ul>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><a aria-label=\"Download a PDF on this Topic. (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/2020_05_14_Tank-level-sensor_J1939_Rev2.0-eng.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Download a PDF on this Topic.<\/a><\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n","protected":false},"excerpt":{"rendered":"<p>In order to monitor the level of the diesel fuel in the tank, you can integrate a tank sensor with SAE J1939-CAN interface in the fpCAN. The tank sensor sends the filling level of the diesel tank in percent on the CAN bus.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[33,14,52],"tags":[],"class_list":["post-3408","post","type-post","status-publish","format-standard","hentry","category-peripheral","category-sae-j1939","category-tank-sensor","entry"],"acf":[],"_links":{"self":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/3408","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3408"}],"version-history":[{"count":21,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/3408\/revisions"}],"predecessor-version":[{"id":4812,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/3408\/revisions\/4812"}],"wp:attachment":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3408"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3408"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3408"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}