{"id":267,"date":"2019-04-12T06:33:35","date_gmt":"2019-04-12T04:33:35","guid":{"rendered":"https:\/\/fpcontrol.fischerpanda.de\/?p=267"},"modified":"2023-04-20T12:43:48","modified_gmt":"2023-04-20T10:43:48","slug":"event-94-ac-voltage-l2-too-high","status":"publish","type":"post","link":"https:\/\/knowledgebase.fischerpanda.de\/?p=267","title":{"rendered":"Event 94 \u2013 AC voltage L2 high"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Event Description<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The AC voltage on phase L2 is above its upper limit.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Error view<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Languages: German | English | Chinese | Spanish | French | Symbolic <\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/event-94_deutsch.jpg\" alt=\"German-language event page of the event 94 for the AC voltage L2 too high\" class=\"wp-image-268\"\/><figcaption class=\"wp-element-caption\"><em>Text view German<\/em><\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/event-94-english.jpg\" alt=\"English-language event page of the event 94 for the AC voltage L2 too high\" class=\"wp-image-269\"\/><figcaption class=\"wp-element-caption\"><em>Text view English<\/em><\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/event-94-chinese.jpg\" alt=\"Chinese-language event page of the event 94 for the AC voltage L2 too high\" class=\"wp-image-270\"\/><figcaption class=\"wp-element-caption\"><em>Text view Chinese<\/em><\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/event-94-spanish.jpg\" alt=\"Spanish-language event page of the event 94 for the AC voltage L2 too high\" class=\"wp-image-271\"\/><figcaption class=\"wp-element-caption\"><em>Text view Spanish<\/em><\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/event-94-french.jpg\" alt=\"French-language event page of the event 94 for the AC voltage L2 too high\" class=\"wp-image-273\"\/><figcaption class=\"wp-element-caption\"><em>Text view French<\/em><\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/event-94-symbolic.jpg\" alt=\"Symbolic view of the event 94 for the AC voltage L2 too high\" class=\"wp-image-274\"\/><figcaption class=\"wp-element-caption\"><em>Symbolic view<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<h4 class=\"wp-block-heading clear\">Elements of the Event page<\/h4>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"857\" height=\"154\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/05\/elements-of-an-error-page.png\" alt=\"Elements of an Event page: Event type, QR-Code, event number and event symbol or text.\" class=\"wp-image-776\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/05\/elements-of-an-error-page.png 857w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/05\/elements-of-an-error-page-300x54.png 300w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/05\/elements-of-an-error-page-768x138.png 768w\" sizes=\"(max-width: 857px) 100vw, 857px\" \/><figcaption class=\"wp-element-caption\"><em>Elements of an Event page: Event type, QR-Code, event number and event symbol or text<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Event symbol<\/strong><\/td><td><strong>Consequences of the event<\/strong><\/td><\/tr><tr><td><img decoding=\"async\" width=\"18\" height=\"17\" class=\"wp-image-66\" style=\"width: 18px;\" alt=\"Error symbol\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/shutdown-symbol.jpg\"> <strong>Error event<\/strong><\/td><td>When an <strong>error event<\/strong> occurs, the monitored value has reached its error limit. Error events <strong>shutdown the generator<\/strong><\/td><\/tr><tr><td><img decoding=\"async\" width=\"19\" height=\"18\" class=\"wp-image-67\" style=\"width: 19px;\" alt=\"Warning symbol\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/warning-symbol.jpg\"> <strong>Warning event<\/strong><\/td><td>When a <strong>warning event<\/strong> occurs, the monitored value has reached its warning limit. Warning Events <strong>don&#8217;t shutdown the generator<\/strong><\/td><\/tr><tr><td><img decoding=\"async\" width=\"17\" height=\"17\" class=\"wp-image-69\" style=\"width: 17px;\" alt=\"Information symbol\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/info-symbol.jpg\"> <strong>Information event<\/strong><\/td><td>An <strong>Information event<\/strong> is for information purpose only and has <strong>no effect on the generator operation<\/strong><\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Device that triggers this event:<\/strong><\/td><td><strong>Generator Control or Inverter<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Warning<\/td><td>No<\/td><\/tr><tr><td><strong>Error<\/strong><\/td><td><strong>Yes<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h4 class=\"wp-block-heading\">Safety instructions<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">These symbols are used to warn of the possibility of personal injury of lethal danger during certain maintenance work or operations. See Users Manual for Safety Information and complete operating information. Read these instructions carefully. For further information click on the corresponding symbol. Each link opens a new tab. <\/p>\n\n\n\n<figure class=\"wp-block-image is-resized\"><a href=\"https:\/\/knowledgebase.fischerpanda.de\/?attachment_id=1652\" target=\"_blank\" rel=\"noreferrer noopener\"><img decoding=\"async\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/08\/read-manual_wei\u00df_klein.jpg\" alt=\"Observe the instructions in the manual\" class=\"wp-image-1652\" width=\"78\" height=\"78\"\/><\/a><figcaption class=\"wp-element-caption\">MANDATORY INSTRUCTION: Observe the instructions in the manual<\/figcaption><\/figure>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft is-resized\"><a href=\"https:\/\/knowledgebase.fischerpanda.de\/?attachment_id=491\" target=\"_blank\" rel=\"noreferrer noopener\"><img decoding=\"async\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/04\/warning_r_general.gif\" alt=\"General warning\" class=\"wp-image-491\" width=\"81\" height=\"70\"\/><\/a><figcaption class=\"wp-element-caption\">General warning<\/figcaption><\/figure>\n<\/div>\n\n\n<h4 class=\"wp-block-heading clear\">Causes and solutions<\/h4>\n\n\n\n<figure class=\"wp-block-table alignwide\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Common causes<\/strong><\/td><td><strong>Possible solutions<\/strong><\/td><\/tr><tr><td>An incorrect setting of the servomotor can lead to an exceeding of the limit value for the AC voltage<\/td><td>Check the servomotor setting and correct the setting, if necessary<\/td><\/tr><tr><td> Over-excitation: The booster capacitors are permanently switched on because the booster relay is stuck <\/td><td>Check the booster relay and replace it, if necessary<\/td><\/tr><tr><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h4 class=\"wp-block-heading\">Distributors and Services<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">For any service or maintenance questions, please contact Fischer Panda or our <a rel=\"noreferrer noopener\" aria-label=\" (opens in a new tab)\" href=\"https:\/\/www.fischerpanda.de\/distributors-and-services.htm\" target=\"_blank\">worldwide partners<\/a>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n","protected":false},"excerpt":{"rendered":"<p>The AC voltage on phase L2 is above its upper limit.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[26],"tags":[],"class_list":["post-267","post","type-post","status-publish","format-standard","hentry","category-event-codes","entry"],"acf":[],"_links":{"self":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=267"}],"version-history":[{"count":14,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/267\/revisions"}],"predecessor-version":[{"id":6721,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/267\/revisions\/6721"}],"wp:attachment":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=267"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=267"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}