{"id":2526,"date":"2019-12-05T09:00:37","date_gmt":"2019-12-05T08:00:37","guid":{"rendered":"https:\/\/fpcontrol.fischerpanda.de\/?p=2526"},"modified":"2020-10-30T10:01:02","modified_gmt":"2020-10-30T09:01:02","slug":"fpcontrol-start-without-inverter","status":"publish","type":"post","link":"https:\/\/knowledgebase.fischerpanda.de\/?p=2526","title":{"rendered":"fpControl &#8211; Start without inverter"},"content":{"rendered":"\n<h3 class=\"h3-weiss-blau wp-block-heading\">Introduction to the topic<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In order to check whether the inverter causes a fault, it is often a first test to start the generator without an inverter. The function &#8220;Start without inverter&#8221; (start w\/o inverter) is an additional start function for this use case. It simulates the engine revolution so that the generator can be started without inverter in case of service.<\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><img decoding=\"async\" width=\"56\" height=\"56\" class=\"wp-image-2536\" style=\"width: 56px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/information_sbu_transparent_52px.png\"><br>The generator control &#8220;fpControl&#8221; receives the engine revolution from the inverter, which sends the value on the CAN interface. The function &#8220;Start without inverter&#8221; simulates the engine revolution. Therefore the start without inverter is possible.<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 id=\"activating_start_woi\" class=\"h3-weiss-blau wp-block-heading\">Activating &#8220;Start without inverter&#8221;  <\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The additional start function can be activated using the control panel. <\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Open menu &#8220;panel&#8221;.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/menu_panel_frame.jpg\" alt=\"\" class=\"wp-image-2648\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Select &#8220;add. start function&#8221; and confirm.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/add-start-function-frame.jpg\" alt=\"\" class=\"wp-image-2649\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Select &#8220;start w\/o inverter&#8221; and confirm. <\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/start-w-o-inverter-frame.jpg\" alt=\"\" class=\"wp-image-2650\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Intermediate result: &#8220;Start without inverter&#8221; is activated. <\/li><\/ul>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Carrying out &#8220;Start without inverter&#8221;  <\/h3>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>NOTICE<\/strong><\/td><\/tr><tr><td><strong>No rotation monitoring \/ evaluation.<\/strong><br>If the generator is started via the &#8220;Start without inverter&#8221; function, no speed evaluation and no speed monitoring are carried out.<br>\u25ba Start the generator without inverter only in case of service.<br><\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>Requirement:<\/strong> The function &#8220;Start without inverter&#8221; must be activated, <a href=\"#activating_start_woi\">see above<\/a>. <\/li><\/ul>\n\n\n\n<table class=\"wp-block-table aligncenter is-style-regular\"><tbody><tr><td><strong>NOTICE<\/strong><\/td><\/tr><tr><td><strong>Property damage to the generator due to continuous operation of the starter.<br><\/strong>If the starter is operated too long, it can overheat.<br>At marine generators cooling water can enter the exhaust system.<br>\u25ba Do not press the start button for more than 10 seconds. Then, pause for 10 seconds.<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Keep [START] pressed until the start speed is reached. <\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">In the control panel an info message appears:<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/start-w-o-inverter-hinweis.jpg\" alt=\"\" class=\"wp-image-2528\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Release [START].<\/li><li>Result: The generator is started.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The control panel displays the event 167 \u2013 &#8220;No rotation monitoring \/ evaluation&#8221;. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/07\/event-167-warning-english.jpg\" alt=\"\" class=\"wp-image-1608\"\/><figcaption><em>Text view English<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img decoding=\"async\" width=\"128\" height=\"64\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/06\/event-167-warning-symbolic.jpg\" alt=\"\" class=\"wp-image-1522\"\/><figcaption><em>Symbolic view<\/em><\/figcaption><\/figure><\/div>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><img decoding=\"async\" width=\"56\" height=\"56\" class=\"wp-image-2536\" style=\"width: 56px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/information_sbu_transparent_52px.png\"><br>fpControl documents with an entry in the event log that the generator was started without an inverter.<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator clear is-style-dots\"\/>\n\n\n\n<h3 class=\"clear h3-weiss-blau wp-block-heading\">Deactivating &#8220;Start without inverter&#8221;  <\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For normal operation of the generator with connected inverter, the function for start without inverter must be deactivated to prevent unintentional use. <\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Open menu &#8220;panel&#8221;.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/menu_panel_frame.jpg\" alt=\"\" class=\"wp-image-2648\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Select &#8220;add. start function&#8221; and confirm.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/add-start-function-frame.jpg\" alt=\"\" class=\"wp-image-2649\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Select &#8220;no function&#8221; and confirm.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/add-function-deactivate-frame.jpg\" alt=\"\" class=\"wp-image-2651\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>Result &#8220;Start without inverter&#8221; is deactivated.<\/li><\/ul>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><a aria-label=\"Download a PDF on this topic. (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/12\/2019_12_05_Start-without-Inverter-Function-Rev01-eng.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Download a PDF on this topic.<\/a><\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-dots\"\/>\n","protected":false},"excerpt":{"rendered":"<p>In order to check whether the inverter causes a fault, it is often a first test to start the generator without an inverter. The function &#8220;Start without inverter&#8221; (start w\/o inverter) is an additional start function for this use case. It simulates the engine revolution so that the generator can be started without inverter in case of service.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[31,5],"tags":[],"class_list":["post-2526","post","type-post","status-publish","format-standard","hentry","category-app-notes-inverter","category-inverter","entry"],"acf":[],"_links":{"self":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/2526","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2526"}],"version-history":[{"count":15,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/2526\/revisions"}],"predecessor-version":[{"id":4356,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/posts\/2526\/revisions\/4356"}],"wp:attachment":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2526"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2526"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2526"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}