{"id":9712,"date":"2026-06-23T14:54:37","date_gmt":"2026-06-23T12:54:37","guid":{"rendered":"https:\/\/knowledgebase.fischerpanda.de\/?p=9712"},"modified":"2026-06-23T14:54:38","modified_gmt":"2026-06-23T12:54:38","slug":"datasheet-xcontrol-control-panel-generator","status":"publish","type":"knowledgebase","link":"https:\/\/knowledgebase.fischerpanda.de\/?knowledgebase=datasheet-xcontrol-control-panel-generator","title":{"rendered":"Datasheet \u00bbxControl Control Panel &#8211; Generator\u00ab"},"content":{"rendered":"\n<h3 class=\"wp-block-heading h3-weiss-blau\">Application<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The \u00bbxControl Control Panel &#8211; Generator\u00ab (xControl CP-G) is intended for use on generators with xControl system. It is the user interface of the control system and is used to operate and display system data. In addition, parameters can be set in the service area.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"wp-block-heading h3-weiss-blau\">Product description<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Automatic start contact to start and stop the generator in addition to the start \/ stop button. <\/li>\n\n\n\n<li>Operating temperature range from -20 \u00b0C to +50 \u00b0C. <\/li>\n\n\n\n<li>Display resolution: 128 x 64 pixels.<\/li>\n\n\n\n<li>Integrated display heater.  <\/li>\n\n\n\n<li>Integrated buzzer for the acoustic output of warnings and errors.<\/li>\n\n\n\n<li>Each \u00bbxControl CP-G\u00ab can also be used as a slave panel and as an update panel for <a aria-label=\"software update (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?p=3377\" target=\"_blank\" rel=\"noreferrer noopener\">software update<\/a>.<\/li>\n\n\n\n<li>When used as an update panel, the \u00bbxControl CP-G\u00ab works like a USB removable storage device on which the update files for all updateable system components can be stored. <\/li>\n\n\n\n<li>Several slave panels can be used in one system.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"612\" height=\"459\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2026\/06\/P1450970_web.jpg\" alt=\"\" class=\"wp-image-9715\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2026\/06\/P1450970_web.jpg 612w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2026\/06\/P1450970_web-300x225.jpg 300w\" sizes=\"(max-width: 612px) 100vw, 612px\" \/><figcaption class=\"wp-element-caption\"><em>\u00bbxControl Control Panel &#8211; Generator\u00ab (xControl C<\/em>P-G)<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"wp-block-heading h3-weiss-blau\">Controls<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Button Symbol<\/strong><\/td><td><strong>Function<\/strong><\/td><\/tr><tr><td><img decoding=\"async\" width=\"71\" height=\"71\" class=\"wp-image-3787\" style=\"width: 71px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/button-on-off-71px.jpg\"><\/td><td>on \/ off<\/td><\/tr><tr><td><img decoding=\"async\" width=\"71\" height=\"71\" class=\"wp-image-3016\" style=\"width: 71px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/11\/fpControl-arrow-up-10mm.jpg\"><\/td><td>up<\/td><\/tr><tr><td><img decoding=\"async\" width=\"71\" height=\"71\" class=\"wp-image-3015\" style=\"width: 71px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/11\/fpControl-arrow-down-10mm.jpg\"><\/td><td>down<\/td><\/tr><tr><td><img decoding=\"async\" width=\"71\" height=\"71\" class=\"wp-image-3014\" style=\"width: 71px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/11\/fpControl-start-stop-10mm.jpg\"><\/td><td>start \/ stop<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"wp-block-heading h3-weiss-blau\">Connectors<\/h3>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter is-resized\"><img decoding=\"async\" width=\"523\" height=\"661\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fpControl-CP-G-Connectors-labels.jpg\" alt=\"Connectors of the \u00bbfpControl CP-G\u00ab\" class=\"wp-image-4378\" style=\"width:392px;height:496px\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fpControl-CP-G-Connectors-labels.jpg 523w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/08\/fpControl-CP-G-Connectors-labels-237x300.jpg 237w\" sizes=\"(max-width: 523px) 100vw, 523px\" \/><figcaption class=\"wp-element-caption\"><em>Connectors of the \u00bbxControl CP-G\u00ab<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Connector<\/strong><\/td><td><strong>Assignment<\/strong><\/td><\/tr><tr><td>X3<\/td><td>Removable disk for update files (USB)<\/td><\/tr><tr><td>X103<\/td><td>Supply voltage and <a href=\"https:\/\/knowledgebase.fischerpanda.de\/?p=3817\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\"\u00bbfpCAN\u00ab (opens in a new tab)\">\u00bbfpCAN\u00ab<\/a><\/td><\/tr><tr><td>X102<\/td><td>Supply voltage and \u00bbfpCAN\u00ab<\/td><\/tr><tr><td>X101<\/td><td>Automatic start contact<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"wp-block-heading h3-weiss-blau\">Pin assignments<\/h3>\n\n\n\n<h5 class=\"wp-block-heading h5-grey-background\">Pin assignment of \u00bbX103\u00ab and \u00bbX102\u00ab for supply voltage and \u00bbfpCAN\u00ab<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">RJ45 socket.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note<\/strong>: <a href=\"#terminating_resistor\">Bus termination<\/a> is required if the \u00bbxControl CP-G\u00ab is the last module in the \u00bbfpCAN\u00ab.<\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Pin<\/strong><\/td><td><strong>Line<\/strong><\/td><\/tr><tr><td>1<\/td><td>CAN high<\/td><\/tr><tr><td>2<\/td><td>CAN low<\/td><\/tr><tr><td>3<\/td><td>GND<\/td><\/tr><tr><td>4<\/td><td>Wake up<\/td><\/tr><tr><td>5<\/td><td>Bus power<\/td><\/tr><tr><td>6<\/td><td>GND<\/td><\/tr><tr><td>7<\/td><td>GND<\/td><\/tr><tr><td>8<\/td><td>Bus power<\/td><\/tr><\/tbody><\/table>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"wp-block-heading h3-weiss-blau\">Environmental specifications and physical data<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Storage temperature<\/td><td>-10 \u00b0C \u2013 +60 \u00b0C<\/td><\/tr><tr><td>Operating temperature<\/td><td>-20 \u00b0C \u2013 +50 \u00b0C<\/td><\/tr><tr><td>Supply voltage<\/td><td>12 V oder 24 V, Automotive (12\u201313,5 V oder 24\u201328 V)<\/td><\/tr><tr><td>Rated current consumption<\/td><td>&lt; 21 mA @ 12 V (without display heating)<br>&lt; 18 mA @ 24 V (without display heating)<\/td><\/tr><tr><td>Max. current consumption<\/td><td>120 mA (including display heating)<\/td><\/tr><tr><td>Current consumption in standby mode \/ off<\/td><td>0 A<\/td><\/tr><tr><td>Housing<\/td><td>ABS plastic<\/td><\/tr><tr><td>Protection class<\/td><td>IP30 (plugged in RJ45 connector)<\/td><\/tr><tr><td>Overall dimensions<\/td><td>120 x 65 x 35 mm (L x B x H), <br>Cutout: 109,2 x 54,5 mm<\/td><\/tr><tr><td>Weight<\/td><td>0,11 kg<\/td><\/tr><tr><td>FP part number<\/td><td>0000557<\/td><\/tr><tr><td>Printed circuit board<\/td><td>FP1403<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"wp-block-heading h3-weiss-blau\">Accessories<\/h3>\n\n\n\n<h5 class=\"wp-block-heading h5-grey-background\">fpCAN patch cable<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Available in different length. With a data transfer rate of 250 kbps and up to 30 nodes, the maximum cable length is 40 meters.  <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td><strong>Length<\/strong><\/td><td><strong>Fischer Panda part number<\/strong><\/td><\/tr><tr><td>25 m<\/td><td>0013474<\/td><\/tr><tr><td>15 m<\/td><td>0004686<\/td><\/tr><tr><td>10 m<\/td><td>0013473<\/td><\/tr><tr><td>6 m<\/td><td>0013472<\/td><\/tr><tr><td>3 m<\/td><td>0013471<\/td><\/tr><tr><td>1 m<\/td><td>0013470<\/td><\/tr><tr><td>0,5 m<\/td><td>0013468<\/td><\/tr><tr><td>0,2 m<\/td><td>0013466<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h5 id=\"terminating_resistor\" class=\"wp-block-heading h5-grey-background\">Terminating resistor<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">The ends of the \u00bbfpCAN\u00ab network must be terminated with a 120 ohm resistor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00bbfpCAN\u00ab terminating resistor 120 Ohm with RJ45 connector, red RAL 3000 with FP logo. Fischer Panda part number 0003022.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter is-resized\"><img decoding=\"async\" width=\"1024\" height=\"878\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-1024x878.jpg\" alt=\"fpCAN termination resistor 120 Ohm with RJ45 connector, red RAL 3000 with FP logo\" class=\"wp-image-3584\" style=\"width:256px;height:220px\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-1024x878.jpg 1024w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-300x257.jpg 300w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-768x659.jpg 768w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert-1568x1345.jpg 1568w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/06\/fpCAN-AbschlussWiderstand-2-Ausschnitt-skaliert.jpg 2046w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n<div class=\"wp-block-post-date__modified-date wp-block-post-date\"><time datetime=\"2026-06-23T14:54:38+02:00\">June 23, 2026<\/time><\/div>","protected":false},"excerpt":{"rendered":"<p>The \u00bbfpControl Control Panel &#8211; Generator\u00ab (fpControl CP-G) is intended for use on generators with xControl or fpControl system. It is the user interface of the control system and is used to operate and display system data. In addition, parameters can be set in the service area.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","knowledgebase_cat":[144],"class_list":["post-9712","knowledgebase","type-knowledgebase","status-publish","hentry","knowledgebase_cat-technical_datasheets_xc","entry"],"acf":[],"_links":{"self":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase\/9712","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase"}],"about":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/types\/knowledgebase"}],"author":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=9712"}],"version-history":[{"count":4,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase\/9712\/revisions"}],"predecessor-version":[{"id":9717,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase\/9712\/revisions\/9717"}],"wp:attachment":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=9712"}],"wp:term":[{"taxonomy":"knowledgebase_cat","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fknowledgebase_cat&post=9712"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}