{"id":5710,"date":"2022-03-18T14:35:23","date_gmt":"2022-03-18T13:35:23","guid":{"rendered":"https:\/\/knowledgebase.fischerpanda.de\/?post_type=knowledgebase&#038;p=5710"},"modified":"2026-07-03T14:23:46","modified_gmt":"2026-07-03T12:23:46","slug":"information-on-icontrol-2-5","status":"publish","type":"knowledgebase","link":"https:\/\/knowledgebase.fischerpanda.de\/?knowledgebase=information-on-icontrol-2-5","title":{"rendered":"Datasheet \u00bbiControl2.5 Generator Control\u00ab"},"content":{"rendered":"\n<h3 class=\"wp-block-heading h3-weiss-blau\">New Control for Inverter Generators<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">There is a new version of the iControl2 controller for the inverter generators. Both the control board and the remote control panel have received a hardware update. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In its new version, the control board is called \u00bbiControl 2.5\u00ab. It is an intermediate step before a completely new control will appear with the \u00bbiControl 3\u00ab version. The control panel comes directly as \u00bbiControl 3 remote control panel\u00ab.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><img decoding=\"async\" width=\"56\" height=\"56\" class=\"wp-image-2536\" style=\"width: 56px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/information_sbu_transparent_52px.png\"><br>The control board and the remote control panel of the new \u00bbiControl 2.5\u00ab are pin-compatible with the previous \u00bbiControl 2\u00ab hardware and have the same dimensions. Therefore the new iControl 2.5 can replace the previous hardware for all generator types with iControl 2 control.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"wp-block-heading h3-weiss-blau\">The iControl 2.5 Control Board<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fischer Panda item number: 0034924<\/li>\n\n\n\n<li>Release: <strong>C:3.01.xxx<\/strong> or higher, <strong>C<\/strong>: Controller | <strong>3<\/strong> Hardware release | <strong>01<\/strong> Software release | <strong>xxx <\/strong>Generator type<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"597\" height=\"429\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2022\/03\/icontrol2.5_cp-g-beschriftet.jpg\" alt=\"Connectors of the iControl 2.5 Control Board\" class=\"wp-image-5716\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2022\/03\/icontrol2.5_cp-g-beschriftet.jpg 597w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2022\/03\/icontrol2.5_cp-g-beschriftet-300x216.jpg 300w\" sizes=\"(max-width: 597px) 100vw, 597px\" \/><figcaption class=\"wp-element-caption\"><em>Connectors of the iControl 2.5 Control Board<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>1<\/td><td>Phase L3 \u00bbIN \/ OUT\u00ab<\/td><\/tr><tr><td>2<\/td><td>Phase L2 \u00bbIN \/ OUT\u00ab<\/td><\/tr><tr><td>3<\/td><td>Phase L1 (load output to inverter)<\/td><\/tr><tr><td>4<\/td><td>Winding L1 (input from winding L1)<\/td><\/tr><tr><td>5<\/td><td>external bus communication interface (j1939 based <a href=\"https:\/\/knowledgebase.fischerpanda.de\/?p=3817\" target=\"_blank\" rel=\"noreferrer noopener\">\u00bbfpCAN\u00ab<\/a>)<\/td><\/tr><tr><td>6<\/td><td>iControl 3 panel<\/td><\/tr><tr><td>7<\/td><td> Wire harness <\/td><\/tr><tr><td>8<\/td><td> Output glow plugs <\/td><\/tr><tr><td>9<\/td><td> Supply voltage U+ <\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"wp-block-heading h3-weiss-blau\">The Control Panel \u00bbiControl 3\u00ab<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fischer Panda item number: 0034806<\/li>\n\n\n\n<li>Release: <strong>P: 3.01.000<\/strong> or higher, P: Panel | <strong>3<\/strong> Hardware release | <strong>01<\/strong> Software release | <strong>000<\/strong> Revision<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The controls are the same as the iControl 2 panel.<\/li>\n\n\n\n<li>The known display pages of the iControl2 panel remain unchanged.<\/li>\n\n\n\n<li>The assignment of the socket for the panel connection cable (1) is pin-compatible with the iControl2 panel.<\/li>\n\n\n\n<li>The automatic start contact is on a separate connection socket (2).<\/li>\n\n\n\n<li>The display pages for error messages have been given a new layout.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"709\" height=\"386\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2022\/03\/icontrol2.5_cp-g_small_beschriftet.jpg\" alt=\"\" class=\"wp-image-5960\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2022\/03\/icontrol2.5_cp-g_small_beschriftet.jpg 709w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2022\/03\/icontrol2.5_cp-g_small_beschriftet-300x163.jpg 300w\" sizes=\"(max-width: 709px) 100vw, 709px\" \/><figcaption class=\"wp-element-caption\"><em>Panda iControl3 panel, backside with connectors, DIP switch and closed housing<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>1<\/strong><\/td><td>5-pin Phoenix socket for panel connecting cable<\/td><\/tr><tr><td><strong>2<\/strong><\/td><td>Automatik start (pins AS 6 and AS 7)<\/td><\/tr><tr><td><strong>3<\/strong><\/td><td>Network, for example Ethernet (for future use)<\/td><\/tr><tr><td><strong>4<\/strong><\/td><td>USB (for future use)<\/td><\/tr><tr><td><strong>5<\/strong><\/td><td>Double DIP switch, switching on\/off the terminating resistors for CAN bus 1 and CAN bus 2<\/td><\/tr><tr><td><strong>6<\/strong><\/td><td>Fischer Panda CAN Bus 2, CAN interface, j1939 based \u00bbfpCAN\u00ab (for future use)<\/td><\/tr><tr><td><strong>7<\/strong><\/td><td>3 universal outputs (for future use)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h5 class=\"wp-block-heading h5-grey-background\">Assignment of the socket for the panel cable<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>1<\/strong><\/td><td>UBUS<\/td><td>white (WH)<\/td><td>Bus supply voltage<\/td><\/tr><tr><td><strong>2<\/strong><\/td><td>GND<\/td><td>brown (BN)<\/td><td>Bus ground<\/td><\/tr><tr><td><strong>3<\/strong><\/td><td>RZL<\/td><td>green (GN)<\/td><td>Exciter wire<\/td><\/tr><tr><td><strong>4<\/strong><\/td><td>CAN Low<\/td><td>grey (GY) <\/td><td>Fischer Panda CAN bus 1<\/td><\/tr><tr><td><strong>5<\/strong><\/td><td>CAN High<\/td><td>pink (PK)<\/td><td>Fischer Panda CAN bus 1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"wp-block-heading h3-weiss-blau\">Inverter Compatibility<\/h3>\n\n\n\n<h5 class=\"wp-block-heading h5-grey-background\">Hardware<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><img decoding=\"async\" width=\"56\" height=\"56\" class=\"wp-image-2536\" style=\"width: 56px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/information_sbu_transparent_52px.png\"><br><strong>Note:<\/strong> The assignment of the socket for the connection cable on the PMGi is pin-compatible with the iControl2 system.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h5 class=\"wp-block-heading h5-grey-background\">Software<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><img decoding=\"async\" width=\"56\" height=\"56\" class=\"wp-image-2536\" style=\"width: 56px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/information_sbu_transparent_52px.png\"><br><strong>Note:<\/strong> The inverter must use the <strong>software release 3.0 or higher<\/strong> to work with <strong>\u00bbiControl 2.5\u00ab<\/strong>.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n<div class=\"wp-block-post-date__modified-date wp-block-post-date\"><time datetime=\"2026-07-03T14:23:46+02:00\">July 3, 2026<\/time><\/div>","protected":false},"excerpt":{"rendered":"<p>There is a new version of the iControl2 controller for the inverter generators. Both the control board and the remote control panel have received a hardware update. <\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","knowledgebase_cat":[151],"class_list":["post-5710","knowledgebase","type-knowledgebase","status-publish","hentry","knowledgebase_cat-tech_data","entry"],"acf":[],"_links":{"self":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase\/5710","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase"}],"about":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/types\/knowledgebase"}],"author":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5710"}],"version-history":[{"count":19,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase\/5710\/revisions"}],"predecessor-version":[{"id":9821,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase\/5710\/revisions\/9821"}],"wp:attachment":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5710"}],"wp:term":[{"taxonomy":"knowledgebase_cat","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fknowledgebase_cat&post=5710"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}