{"id":5574,"date":"2021-10-29T13:44:48","date_gmt":"2021-10-29T11:44:48","guid":{"rendered":"https:\/\/knowledgebase.fischerpanda.de\/?post_type=knowledgebase&#038;p=5574"},"modified":"2025-09-15T12:10:18","modified_gmt":"2025-09-15T10:10:18","slug":"hybrid-charger-test","status":"publish","type":"knowledgebase","link":"https:\/\/knowledgebase.fischerpanda.de\/?knowledgebase=hybrid-charger-test","title":{"rendered":"Hybrid Charger\u00a0\u2013\u00a0Power Supply"},"content":{"rendered":"\n<h3 class=\"h3-weiss-blau wp-block-heading\">Supply of the Hybrid-Charger Power Electronic<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The VS-Generator system includes a power electronic component for energy conversion from three phase AC to DC. This power converter is the \u00bbHybrid-Charger\u00ab.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The power supply lines of the Hybrid-Charger are connected to the terminal block, boost relay \/ DC-PMGI plus and minus on the <a rel=\"noreferrer noopener\" aria-label=\"\u00bbfpControl Connection Board - Generator\u00ab (fpControl CB-G) (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?knowledgebase=datasheet-fpcontrol-connection-board-generator\" target=\"_blank\">\u00bbfpControl Connection Board &#8211; Generator\u00ab (fpControl CB-G)<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"1024\" height=\"383\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2021\/10\/connection-board-cb-g-x8-1024x383.jpg\" alt=\"\u00bbfpControl Connection Board \u2013 Generator\u00ab (fpControl CB-G) with marked connector X8 for boost relay or DC power supply inverter\" class=\"wp-image-5591\" srcset=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2021\/10\/connection-board-cb-g-x8-1024x383.jpg 1024w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2021\/10\/connection-board-cb-g-x8-300x112.jpg 300w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2021\/10\/connection-board-cb-g-x8-768x287.jpg 768w, https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2021\/10\/connection-board-cb-g-x8.jpg 1067w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><em>\u00bbfpControl Connection Board \u2013 Generator\u00ab (fpControl CB-G) with marked connector X8 for boost relay or DC power supply inverter<\/em><\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The supply voltage on the terminal block output will be controlled by the Generator Control <a rel=\"noreferrer noopener\" aria-label=\"\u00bbfpControl Generator Control - Servo\u00ab (fpControl GC-S) (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?knowledgebase=datasheet-fpcontrol-generator-control-servo\" target=\"_blank\">\u00bbfpControl Generator Control &#8211; Servo\u00ab (fpControl GC-S)<\/a>. The Generator Control controls the supply of the Hybrid-Charger in most efficient way.  <\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><img decoding=\"async\" width=\"56\" height=\"56\" class=\"wp-image-2536\" style=\"width: 56px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/information_sbu_transparent_52px.png\"><br>If there is an error message or an emergency stop signal, the hybrid charger is always switched off. This is independent of the menu setting.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Automatic supply<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In normal operation the fpControl switches on the Hybrid-Charger for 30 seconds after system start. In this time a system check and a check for updates are performed. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If the generator system remains in standby mode and the motor does not start, the Generator Control switches off the Hybrid-Charger supply after 30 seconds. At a motor start command the Hybrid-Charger will be switched on immediately. <\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\">Switching on supply manually<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In some cases, for example, service or configuration of the converter, the Hybrid-Charger should be on continuously. In this case the supply can be switched on manually by the  <br><a rel=\"noreferrer noopener\" aria-label=\"\u00bbfpControl Control Panel - Generator\u00ab (fpControl CP-G) (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?knowledgebase=datasheet-fpcontrol-control-panel-generator\" target=\"_blank\">\u00bbfpControl Control Panel &#8211; Generator\u00ab (fpControl CP-G)<\/a>. The Hybrid Charger supply remains in on mode until the next system start. After a restart of the Generator Control the FP-Control takes over the control of the power supply again. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The following converter menu is only displayed if a VS-Generator type is selected (<a rel=\"noreferrer noopener\" aria-label=\"Generator type codes (opens in a new tab)\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?knowledgebase_cat=generator_types\" target=\"_blank\">Generator type codes<\/a> 3000 &#8211; 3999).  <\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Function call<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Panel menu: <strong>converter &gt; power supply &gt; turn on \/ off<\/strong>.<\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Step by step guide<\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Open menu item <strong>\u00bbconverter\u00ab<\/strong>. <\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2021\/10\/converter.jpg\" alt=\"\" class=\"wp-image-5587\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select <strong>\u00bbpower supply\u00ab<\/strong>. <\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2021\/10\/power_supply.jpg\" alt=\"\" class=\"wp-image-5588\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select <strong>\u00bbon\u00ab<\/strong> to <strong>switch on<\/strong> \/ <strong>\u00bboff\u00ab<\/strong> to <strong>switch off<\/strong> the power supply and confirm. <\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2021\/06\/off_on_back.jpg\" alt=\"\" class=\"wp-image-4788\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select <strong>\u00bbconfirm\u00ab<\/strong>. <\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/confirm-frame.jpg\" alt=\"\" class=\"wp-image-3555\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Result:<\/strong> The power supply is switched on manually. <\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n","protected":false},"excerpt":{"rendered":"<p>The VS-Generator system includes a power electronic component for energy conversion from three phase AC to DC. This power converter is the \u00bbHybrid-Charger\u00ab.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","knowledgebase_cat":[161],"class_list":["post-5574","knowledgebase","type-knowledgebase","status-publish","hentry","knowledgebase_cat-hybrid-charger","entry"],"acf":[],"_links":{"self":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase\/5574","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase"}],"about":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/types\/knowledgebase"}],"author":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5574"}],"version-history":[{"count":11,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase\/5574\/revisions"}],"predecessor-version":[{"id":6433,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase\/5574\/revisions\/6433"}],"wp:attachment":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5574"}],"wp:term":[{"taxonomy":"knowledgebase_cat","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fknowledgebase_cat&post=5574"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}