{"id":5410,"date":"2021-09-01T10:57:40","date_gmt":"2021-09-01T08:57:40","guid":{"rendered":"https:\/\/knowledgebase.fischerpanda.de\/?p=5410"},"modified":"2025-05-19T09:27:48","modified_gmt":"2025-05-19T07:27:48","slug":"the-tank-refill-function-of-fpcontrol","status":"publish","type":"knowledgebase","link":"https:\/\/knowledgebase.fischerpanda.de\/?knowledgebase=the-tank-refill-function-of-fpcontrol","title":{"rendered":"fpControl \u2013 Tank refill function"},"content":{"rendered":"\n<table class=\"wp-block-table\"><tbody><tr><td><img decoding=\"async\" width=\"56\" height=\"56\" class=\"wp-image-2536\" style=\"width: 56px;\" alt=\"\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/10\/information_sbu_transparent_52px.png\"><br><strong>Note:<\/strong> This function is not available with every generator. Check in each individual case whether the function can be used with your generator.<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\" id=\"introduction\">Introduction to the topic<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">With the tank refill function of fpControl you can refill the integrated tank of the generator with diesel fuel from a separate additional tank. <\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\">Functional description of the tank refill<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">The tank refill function has two different operating modes: <\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>You can <a href=\"#configuring_multifunc_out\">configure the multifunction output 2 (5 A)<\/a> of the \u00bbfpControl GC-S\u00ab directly as an output for the external fuel pump. The output then switches the fuel pump on and off depending on the filling level supplied by the CAN bus tank sensor. <\/li>\n\n\n\n<li>You can <a href=\"#configuring_multifunc_in\">configure one of the multifunction inputs<\/a> of the \u00bbfpControl GC-S\u00ab so that you can switch the tank refill function on and off via this input. In this case the multifunction output (5 A) of the \u00bbfpControl GC-S\u00ab is automatically configured as an output for the external fuel pump. The output then switches the fuel pump on and off depending on the status of the digital input AND the filling level supplied by the CAN bus tank sensor.  <br><strong>The procedure in detail:<\/strong> The \u00bbfpControl GC-S\u00ab evaluates the status of the multifunctional input. If this input has the status \u00bb0\u00ab, the tank refill function is switched off. If it has the status \u00bb1\u00ab, the multifunction output for the external fuel pump is switched on when the <a href=\"#thresholds_filling_level\">threshold for \u00bbrefilling\u00ab<\/a> is reached. If the threshold for \u00bbstop refilling\u00ab is reached, the output is switched off. <br><strong>There is one special feature in this case<\/strong>: When you switch on the digital input, the external fuel pump is switched on in any case and the integrated tank of the generator is filled to a level of 100 %. This takes place regardless of the filling level supplied by the CAN bus tank sensor.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\" id=\"hardware_requirements\">Hardware Requirements<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Generator with <a aria-label=\"\u00bbfpControl Generator Control - Servo\u00ab (fpControl GC-S) (opens in a new tab)\" rel=\"noreferrer noopener\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?p=3762\" target=\"_blank\">\u00bbfpControl Generator Control &#8211; Servo\u00ab (fpControl GC-S)<\/a><\/li>\n\n\n\n<li>and <a aria-label=\"\u00bbfpControl Control Panel - Generator\u00ab (fpControl CP-G) (opens in a new tab)\" rel=\"noreferrer noopener\" href=\"https:\/\/knowledgebase.fischerpanda.de\/?p=3780\" target=\"_blank\">\u00bbfpControl Control Panel &#8211; Generator\u00ab (fpControl CP-G)<\/a><\/li>\n\n\n\n<li>ITS-60 <a href=\"https:\/\/knowledgebase.fischerpanda.de\/?knowledgebase=j1939-tank-sensor-for-fpcan\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\" (opens in a new tab)\">Tank Sensor for fpCAN<\/a> to measure the filling level of the integrated tank<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\" id=\"software_requirements\">Software Requirements<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00bbfpControl Generator Control &#8211; Servo\u00ab (fpControl GC-S): <strong>V000R06 or higher<\/strong><\/li>\n\n\n\n<li>\u00bbfpControl Control Panel &#8211; Generator\u00ab (fpControl CP-G): <strong>V005R04 or higher<\/strong><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n\n\n\n<h3 class=\"h3-weiss-blau wp-block-heading\" id=\"activating_tank_refill\">Configuring the tank refill<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Configuring the tank refill function using the service menu of the \u00bbfpControl CP-G\u00ab. <\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\" id=\"configuring_multifunc_out\">Configuring the multifunction output 2 (5 A) <\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">To get the multifunction output switching the external fuel pump the corresponding profile must be assigned.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Requirement:<\/strong> To set the mode of the multifunction output 2 you must enter the service password or have admin rights while the function is being called.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Function call:<\/strong> service &gt; enter service-code &gt; multifunc. outputs &gt; mode of output 2 &gt; external fuelpump <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step by step guide<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Setting the mode of the multifunction output 2 to &#8220;external fuelpump&#8221;:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Open menu &#8220;service&#8221;.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/09\/main-menu-service.jpg\" alt=\"\" class=\"wp-image-3876\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Enter the service password.<\/li>\n\n\n\n<li>Select &#8220;multifunc. outputs&#8221; and confirm. <\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/09\/tank_refill_multifunc_outputs.jpg\" alt=\"\" class=\"wp-image-3953\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select &#8220;mode of output 2&#8221; and confirm. <\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/09\/tank_refill_mode_of_output.jpg\" alt=\"\" class=\"wp-image-3952\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select &#8220;external fuelpump&#8221; and confirm. <\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/09\/tank_refill_external_fuelpump.jpg\" alt=\"\" class=\"wp-image-3951\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Result:<\/strong> The multifunction output 2 of the \u00bbfpControl GC-S\u00ab is set to &#8220;external fuelpump&#8221;.<\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\" id=\"configuring_multifunc_in\">Configuring one of the multifunction inputs<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">The multifunction inputs of the \u00bbfpControl GC-S\u00ab can perform different functions. To get an digital input switching the tank refill function the corresponding profile must be assigned to input 1 or 2.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Function call:<\/strong> service &gt; enter service-code &gt; multifunc. inputs &gt; mode of input 1 (2) &gt; ext. fp on out 1 (2) <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step by step guide<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Open menu &#8220;service&#8221;.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/09\/main-menu-service.jpg\" alt=\"\" class=\"wp-image-3876\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select &#8220;multifunc. inputs&#8221; and confirm.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/09\/tank_refill_multifunc_inputs.jpg\" alt=\"\" class=\"wp-image-3957\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select &#8220;mode of input 1&#8221; (respectively &#8220;mode of input 2&#8221;) and confirm.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/09\/tank_refill_mode_of_input_2.jpg\" alt=\"\" class=\"wp-image-3956\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select &#8220;ext. fp on out 2&#8221; and confirm.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/09\/tank_refill_ext_fp_on_out_2.jpg\" alt=\"\" class=\"wp-image-3955\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select &#8220;confirm&#8221;.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"131\" height=\"68\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2019\/11\/cancel_confirm-page.jpg\" alt=\"\" class=\"wp-image-3153\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Result:<\/strong> The multifunction input 2 of the \u00bbfpControl GC-S\u00ab is set to switch the tank refill function on and off.<\/p>\n\n\n\n<h5 class=\"h5-grey-background wp-block-heading\" id=\"thresholds_filling_level\">Setting the switch-on and switch-off threshold values for the filling level<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">You can set the minimum level at which the external fuel pump should be switched on and the maximum level at which it should be switched off.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Requirement:<\/strong> To set the switch-on and switch-off threshold, the CAN bus tank sensor must be connected to the \u00bbfpCAN\u00ab.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Function call:<\/strong> generator &gt; fuel thresholds &gt; ext. FP on (off)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step by step guide<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Open menu &#8220;generator&#8221;.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/09\/tank_refill_main_generator.jpg\" alt=\"\" class=\"wp-image-3989\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select &#8220;fuel thresholds&#8221; and confirm.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/09\/tank_refill_fuel_thresholds.jpg\" alt=\"\" class=\"wp-image-3990\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select &#8220;ext. FP on&#8221; and confirm.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/09\/tank_refill_ext_FP_on.jpg\" alt=\"\" class=\"wp-image-3987\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Set the switch-on threshold between its specified minimum and maximum values and confirm.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/09\/tank_refill_ext_FP_on_value.jpg\" alt=\"\" class=\"wp-image-3988\"\/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Select &#8220;confirm&#8221;.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"130\" height=\"66\" src=\"https:\/\/knowledgebase.fischerpanda.de\/wp-content\/uploads\/2020\/05\/confirm-frame.jpg\" alt=\"\" class=\"wp-image-3555\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Repeat the steps for the switch-off value.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Result:<\/strong> The switch-on and switch-off threshold for the external fuel pump are stored.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-dots\"\/>\n","protected":false},"excerpt":{"rendered":"<p>With the tank refill function of fpControl you can refill the integrated tank of the generator with diesel fuel from a separate additional tank.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","knowledgebase_cat":[146],"class_list":["post-5410","knowledgebase","type-knowledgebase","status-publish","hentry","knowledgebase_cat-application_notes_fpc","entry"],"acf":[],"_links":{"self":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase\/5410","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase"}],"about":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/types\/knowledgebase"}],"author":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5410"}],"version-history":[{"count":3,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase\/5410\/revisions"}],"predecessor-version":[{"id":6549,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=\/wp\/v2\/knowledgebase\/5410\/revisions\/6549"}],"wp:attachment":[{"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5410"}],"wp:term":[{"taxonomy":"knowledgebase_cat","embeddable":true,"href":"https:\/\/knowledgebase.fischerpanda.de\/index.php?rest_route=%2Fwp%2Fv2%2Fknowledgebase_cat&post=5410"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}