Generator type codes for the generator control iControl2

Generator types for the generator control iControl2.

Posted byFischer PandaDecember 18, 2019October 30, 2020Posted iniControl2

Inverter softstart with fpControl

You can use the additional start function “inverter softstart” to avoid problems when starting large electrical loads. If this function is activated, the inverter carries out measures at start-up to limit the power when switching on the loads (softstart).

Posted byFischer PandaDecember 6, 2019October 30, 2020Posted inApplication Notes Inverter, Inverter

fpControl – Start without inverter

In order to check whether the inverter causes a fault, it is often a first test to start the generator without an inverter. The function “Start without inverter” (start w/o inverter) is an additional start function for this use case. It simulates the engine revolution so that the generator can be started without inverter in case of service.

Posted byFischer PandaDecember 5, 2019October 30, 2020Posted inApplication Notes Inverter, Inverter

Adjusting the parameters for the battery loader with fpControl

You can set the charging curve parameters of the battery loader. This is necessary to adapt the battery loader to different battery types.

Posted byFischer PandaDecember 3, 2019November 9, 2020Posted inAGT, Application Notes fpC, fpControl

News

  • Event 172 – Synchronization Module offline December 18, 2020
  • Event 171 – Load Contactor switched off forced December 18, 2020
  • Start repetitions in automatic start mode November 26, 2020
  • Inverter blink codes November 13, 2020
  • Parallel connection of two asynchronous generators November 10, 2020

Categories

  • AGT
  • Application Notes fpC
  • Application Notes Inverter
  • Communication
  • Event Codes
  • fpControl
  • iControl2
  • Inverter
  • Multifunction Displays
  • NMEA 2000®
  • SAE J1939
  • Software Update
  • System
  • Technical Datasheets fpC
  • Technical Datasheets iC2
  • Technical Datasheets Inverter
  • Victron GX

Archive

  • December 2020
  • November 2020
  • October 2020
  • September 2020
  • August 2020
  • July 2020
  • June 2020
  • May 2020
  • April 2020
  • January 2020
  • December 2019
  • November 2019
  • October 2019
  • September 2019
  • July 2019
  • June 2019
  • May 2019
  • April 2019

Search …

Fischer Panda, Proudly powered by WordPress. Data Protection Policy
  • Site Terms & Conditions (Impressum)
  • Home
  • Glossary
  • Service